Type NR oil switch installation and operation instructions

INSTALLATION AND OPERATION INSTRUCTIONS

   MN230008EN   November 2016

Product information

Introduction

Service Information MN230008EN provides installation 

instructions, operation information and testing procedures 

for the Type NR oil switch.
The information contained in this manual is organized 

into the following major categories; Safety Information, 

Product Information, Ratings and Specifications, Installation 

Procedure, Switch Operation, Dimensions and Weights, and 

Maintenance Information. Refer to the Table of Contents for 

page numbers.

Read this manual first

Read and understand the contents of this manual and follow 

all locally approved procedures and safety practices before 

installing or operating this equipment.

Additional information

These instructions cannot cover all details or vari ations 

in the equipment, procedures, or process described, nor 

provide directions for meeting every possible contin gency 

during installation, operation, or maintenance. When 

additional information is desired to satisfy a problem not 

cov ered sufficiently for the user’s purpose, please contact 

your Eaton’s Cooper Power series product representative.

Acceptance and initial inspection

Each switch is completely assembled, inspected, tested and 

adjusted at the factory and is filled to the correct level with 

insulating oil. It is in good condition when accepted by the 

carrier for shipment. Upon receipt of a switch:
1.  Inspect the switch thoroughly for damage and loss of 

parts or oil incurred during shipment. If damage or loss 

is discovered, file a claim with the carrier immediately.

2.  Check for oil leakage and tighten all bolts that may have 

loosened during shipment, especially the bolts attaching 

the head to the tank.

Handling and storage

If the switch is to be stored for an appreciable time before 

installation, provide a clean, dry storage area. Locate the 

switch so as to minimize the possibility of mechanical 

damage, particularly to the bushings.

Description of operation

The Type NR oil switch is a single-phase device for use on 

distribution circuits. Compact design makes this switch ideal 

for use on capacitor banks, especially pole-top installations. 

This switch is electrically operated and can be controlled by 

time switches, voltage- or current-sensitive control devices, 

or by single-pole, double-throw switches. An operating 

handle, which also serves as a contact position indicator, 

is provided for manually opening and closing the switch.

 WARNING 

Never manually close this switch into a faulted line . The 

make-and-latch rating of the switch applies only when 

it is electrically operated . Closing a switch manually on 

a faulted line can result in death, severe personal injury, 

and equipment damage . 

G127 .0

Check switch ratings prior to installation

The switch must be applied within its specified ratings. 

Check data plate ratings and compare with the system 

characteristics at the point of application, prior to 

installation. Tables 1 and 2 list the specifications and ratings 

for the Type NR oil switch.

Quality standards

ISO 9001 Certified Quality Management System

Summary of Contents for NR

Page 1: ...Type NR oil switch installation and operation instructions COOPER POWER SERIES Oil Switches MN230008EN Effective November 2016 Supersedes October 2013 S260 20 1...

Page 2: ...ICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUME...

Page 3: ...d storage 1 Description of operation 1 Check switch ratings prior to installation 1 Quality standards 1 RATINGS AND SPECIFICATIONS 2 INSTALLATION PROCEDURE 3 Check out procedure 3 Main wiring 3 Contro...

Page 4: ...en working around high voltage lines and equipment and support our Safety For Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe persona...

Page 5: ...ch 1 Inspect the switch thoroughly for damage and loss of parts or oil incurred during shipment If damage or loss is discovered file a claim with the carrier immediately 2 Check for oil leakage and ti...

Page 6: ...Basic Insulation Level BIL kV 95 95 125 125 60 Hertz withstand voltage kV Dry one minute Wet ten seconds 35 30 35 30 42 36 60 50 Continuous current rating Amps 200 200 200 60 Load interrupting ability...

Page 7: ...eration CLOSE and OPEN the switch contacts manually using the yellow operating handle Confirm that the contacts have closed and opened by listening for the sound of operation or by a continuity check...

Page 8: ...n diagram for a standard three wire control is shown in Figure 2 NOTE G Ground 2 Close 3 Open MOTOR 0 1 G 2 3 4 Black Red AC White DC Black AC Black DC Red SEL SW NO MO C NC A B C Close Recaptacle ACC...

Page 9: ...cally by applying rated control voltage to the proper terminals of the actuator terminal block If the switch actuator does not respond to an electrical operating signal it may be that the main switch...

Page 10: ...capacity 1 1 2 gal 1 06 OPENING FOR FACTORY WIRED RECEPTACLE 44 HOLES 4 1 5 4 75 1 25 10 75 1 25 5 5 22 38 4 5 8 25 2 75 13 88 5 62 7 12 1 38 HOLE 8 0 2 0 14 25 7 88 8 SOLID TO 2 0 STRD BUSHING TERMI...

Page 11: ...maintained it may fail to operate properly Maintenance manual Maintenance instructions for Type NR oil switch is provided in Service Information MN230001EN Reference TD280022EN provides information on...

Page 12: ...188 United States Eaton com cooperpowerseries 2016 Eaton All Rights Reserved Publication No MN230008EN November 2016 SAFETY FOR LIFE Eaton is a registered trademark All trademarks are property of thei...

Reviews: