background image

Display/Operator
System for CANopen

MFD-CP4-CO,
MFD-80

Hardware and Engineering

05/08 AWB2528-1611en

Summary of Contents for Moeller MFD-80

Page 1: ...Display Operator System for CANopen MFD CP4 CO MFD 80 Hardware and Engineering 05 08 AWB2528 1611en...

Page 2: ...bert Einwag Editor Thomas Kracht Translator Dominik Kreuzer All rights reserved including those of the translation No part of this manual may be reproduced in any form printed photocopy microfilm or a...

Page 3: ...ey are well protected against unintentional operation Suitable safety hardware and software measures should be implemented for the I O interface so that a line or wire breakage on the signal side does...

Page 4: ...states even for a short time If necessary emergency stop devices should be implemented Wherever faults in the automation system may cause damage to persons or property external measures must be imple...

Page 5: ...2 Installation 11 Mounting 11 Fitting the protective membrane 12 Mounting the protective cover 13 Mounting the display operating unit front mounting 16 Removing the display operating unit front mounti...

Page 6: ...80 XM protective diaphragm 27 MFD 80 XS protective cover 28 Communication module MFD CP4 CO 28 Technical data 29 General ambient conditions 29 MFD 80 display operating unit 31 MFD XM 80 protective di...

Page 7: ...cal engineering is needed for commissioning Plant sections may be damaged if the display operator system is incorrectly connected or incor rectly programmed Additional manuals The description of the d...

Page 8: ...page and the name of the current section in the header of the right hand page This does not apply to pages at the start of a chapter and empty pages at the end of a chapter h Caution Warns of the ris...

Page 9: ...e following indi vidual components MFD 80 display operator unit Communication module MFD CP4 CO CANopen connection cable for connecting a Moeller PLC such as EU4A RJ45 CAB2 for connecting an EC4P Figu...

Page 10: ...c page provides space for up to 4 variables The variables can be displayed and edited Instead of embedding variables the basic page can also be run in scrolling mode In this mode you can add lines to...

Page 11: ...a start page Operator functions Baud rate and Node ID setting The baud rate and node ID are set via a configuration menu which you can call up irrespective of the display s fieldbus status The device...

Page 12: ...SY_HMI MFD CP4 CO Setup Display operating unit Figure 4 Display operating unit a DEL button b Graphic display c ALT button d LEDs for signalling e Mode button f Right down cursor buttons g OK button h...

Page 13: ...Setup 9 05 08 AWB2528 1611en Communication module Figure 5 Communication module a Power supply b CANopen interface Key to part numbers MFD CP4 CO CANopen CP4 CPU Multi function display a b...

Page 14: ...10 05 08 AWB2528 1611en...

Page 15: ...r in an enclosure You can protect the display operator unit with a protective membrane or cover depending on the environ ment in which it is to be used This must be fitted before the MFD CP4 CO is mou...

Page 16: ...ing the protective membrane a Protective diaphragm b Display and operating unit h Fit the protective membrane before mounting the display operator unit a b i Danger Ensure that the diaphragm fits snug...

Page 17: ...echanical damage or destruction Protection to IP 65 is maintained The protective cover can be opened so that the operating unit can be used The protective cover can be closed with a sealing facility t...

Page 18: ...t frame before mounting Figure 9 Removing the front frame The protective cover can be mounted in two different posi tions X Choose the position that is most suitable for the applica tion at hand and y...

Page 19: ...gure 12 Sealing the protective cover The grip handle of the protective cover is provided with holes that can be used in any mounting position You can fit a wire or similar material through these holes...

Page 20: ...trol circuit devices Figure 13 Drill holes for the MFD h The protective membrane or the protective cover must be fitted beforehand h Observe the following technical requirements The hole spacing is 30...

Page 21: ...igure 14 Mounting the display operator unit X Tighten the display operator unit with the M22 MS combi nation box spanner a figure 15 The tightening torque must be between 1 2 and 2 Nm h Ensure that th...

Page 22: ...11en Figure 15 Screw fastening the display operating unit Figure 16 Rear of the mounted display operator unit Removing the display operating unit front mounting X Unscrew the fixing element and remove...

Page 23: ...Mounting 19 05 08 AWB2528 1611en Mount communication module Figure 17 Mount communication module...

Page 24: ...m the fixing shafts Figure 18 Releasing the fixing shaft Connections Terminals The MFD CP4 CO is fitted with cage clamp terminals for connecting the power supply and the connection cable to the CANope...

Page 25: ...n F1 of at least 1 A slow on the MFD CP4 CO h The required connection data for the MFD CP4 CO is provided in the section Technical data page 29 0V 24V 0 6 x 3 5 x 100 L01 L02 L01 1 A Ue 24 V H 20 4 28...

Page 26: ...r carefully X Use a screwdriver to press down the recess next to the terminal and connect the wires of the connection cable to the terminals in the order stated Proceed accordingly in the reverse orde...

Page 27: ...ou can use the EU4A RJ45 CAB2 cable to connect the MFD CP4 CO to an EC4P Figure 21 Connecting the MFD CP4 CO to EC4P Connector type 6 pole cage clamp terminal block cable connections up to 0 5 mm2 RJ4...

Page 28: ...cage clamp terminal block cable connections up to 0 5 mm2 Bus terminating resistors 120 O bus terminating resistors must be used at the ends of the network Figure 23 Possible configuration of a CANope...

Page 29: ...y mode Entry mode enables you to change the setting using the and buttons Pressing the OK button again stores the actual value Pressing the button in the last line causes the current soft ware version...

Page 30: ...dresses with the and buttons X Press the OK button again to save the value The next time the power supply is switched off and on the device will try to connect to the new address j Danger The display...

Page 31: ...27 05 08 AWB2528 1611en Appendix Dimensions MFD 80 display operating unit MFD 80 XM protective diaphragm 32 17 20 13 7 86 5 30 g0 2 62 86 5 28 25 28 25 22 3 0 4 30 88 5 22 5 88 5...

Page 32: ...Appendix 28 05 08 AWB2528 1611en MFD 80 XS protective cover Communication module MFD CP4 CO 86 5 25 95 75 58 36 2 30 22 5 22 5...

Page 33: ...158 Relative humidity IEC 60068 2 30 non condensing 5 to 95 Air pressure in operation hPa 795 to 1080 Ambient mechanical conditions Pollution degree Power supply unit CPU 2 Display operating unit 3 D...

Page 34: ...V 2 High energy pulses Surge MFD IEC EN 61000 4 5 severity level 2 power cable symmetrical kV 1 Line conducted interference IEC EN 61000 4 6 V 10 Insulation resistance Overvoltage category II Clearanc...

Page 35: ...ximum mm 1 6 inches 0 04 0 24 Weight g 130 lb 0 287 Mounting 2 22 5 mm 0 886 in holes Display fastened with two fixing rings Maximum tightening torque of the fixing rings Nm 1 2 to 2 Power supply via...

Page 36: ...nation LED Number 5 Colour green Dimensions W x H x D mm 88 x 88 x 25 inches 3 46 x 3 46 x 0 98 Weight g 25 lb 0 055 Mounting Is fitted over the display keypad with Titan front ring Dimensions W x H x...

Page 37: ...ge V DC 20 4 28 8 Residual ripple F 5 Input current for 24 V DC MFD CP4 CO MFD 80 mA normally 150 Voltage dips IEC EN 61131 2 ms 10 Heat dissipation for 24 V DC MFD CP4 CO MFD 80 W normally 3 6 CANope...

Page 38: ...34 05 08 AWB2528 1611en...

Page 39: ...Changing parameters 25 Commissioning 26 Communication module Mounting 19 Technical data 33 Connection Cross sections 30 Supply voltage 21 Terminals 20 Contrast 25 D Dimensions 27 Display functions 7 D...

Page 40: ...in a control panel 11 Mounting Communication module 19 Display Operating unit 16 Protective cover 13 Protective diaphragm 12 N Node ID 25 Node Id setting 8 O Operator functions 8 P Polarity 21 Power...

Page 41: ...polarity protection 21 S Sealing the protective cover 15 Settings 25 Setup menu 25 Software version 25 Station address 25 Supply voltage Connecting 21 T Technical data 29 Tools 30 Type code Communica...