![Eaton LVLD Series Installation Instructions Manual Download Page 5](http://html.mh-extra.com/html/eaton/lvld-series/lvld-series_installation-instructions-manual_3822199005.webp)
5
www.eaton.com
CGL+
6
4 5
3
1 2
8
7
IN +
LED R
LED B
1h: 3h:
CV 12V
:
C
G
Line+ Bus
OUT + OUT -
IN -
Red
Brown
Indicating Bicolor
LE
D
CGL+ CGL+
6
4 5
3
1 2
8
7
IN +
LED
Y
LED W
1h: 3h:
CV 12V
:
DALI Bus
OUT + OUT -
IN -
White
Yellow
DALI
Indicating Bicolor LED
DALI
DALI
LE
D
6
4
5
3
1
2
8
7
LED Y
LED W
TL B+
TL A-
IN -
OUT -
OUT +
IN +
-
+9Vdc
Telecommand
6
4
5
3
1
2
8
7
LED Y
LED W
TL B+
TL A-
IN -
OUT -
OUT +
IN +
est by Normally Closed Switch
NC
Test options
6
4 5
3
1 2
8
7
IN +
LED
LED
1h: 3h:
CV 12V
:
Bus
OUT + OUT -
IN -
Brown/White
Red/Yellow
NC
CGL+/DALI
Indicating Bicolor LED
6
4 5
3
1 2
8
7
LED
Y
LED W
TL
B+
TL
A-
IN -
OUT -
OUT +
IN +
230V
ac
- +9Vdc
Test by
Telecommand
6
4 5
3
1 2
8
7
LED
Y
LED W
TL
B+
TL
A-
IN -
OUT -
OUT +
IN +
230V
ac
Test by Normally Closed Switch
6
4 5
3
1 2
8
7
LED
Y
LED W
TL
B+
TL
A-
IN -
OUT -
OUT +
IN +
230V
ac
Test by Normally Open Switch
N
C
N
O
6
4 5
3
1 2
8
7
LED
Y
LED W
TL
B+
TL
A-
IN -
OUT -
OUT +
IN +
0V
ac
Emergency to Rest by
Telecommand
Telecommand Signal
- +9Vdc
=
TL
A-
TL
B+
-
+ 9Vdc
=
TL
A-
TL
B+
Emergency
6
4 5
3
1 2
8
7
LED
Y
LED W
TL
B+
TL
A-
IN -
OUT -
OUT +
IN +
0V
ac
Telecommand Signal
Rest
6
4 5
3
1 2
8
7
IN +
LED
LED
1h: 3h:
CV 12V
:
Bus
OUT + OUT -
IN -
Red/White
Brown/Y
ellow
NC
Test by Normally Closed Switch
CGL+/DALI
Indicating Bicolor LED
Test options
Telecommand
Replacement
Contact sales with the unit or the battery order code
Fixing centers
4AA
100 (140) 30 (34) 15 (20) (125)
3Cs
130 (160) 25 (26) 25 (26) (150)
4Cs
173 (203) 25 (26) 25 (26) (193)
5Cs
215 (245) 25 (26) 25 (26) (235)
3D
182 (225) 34 (35) 34 (35) (210)
4D
242 (285) 34 (35) 34 (35) (270)
Li
fe
Po4
134 (173) 31 (32) 31 (32) (157)
Type
L
W
H
Values inside parentheses re
fer to ba
tteries with mounting caps.
Self test sequence CGL+
@installation
Lamp
B
at
ter
y
1 week +12h
1 week
1 week
1 week
1 week +12h @ EVEN
2 weeks +12h @ ODD
26 weeks
26 weeks
26 weeks
26 weeks
Self test sequence CGL+
@operation
Lamp
B
at
ter
y
1 week
1 week
1 week
26 weeks @ EVEN
27 weeks @ ODD
CGL+,
Bi-color LED
Test
Green:
Green:
Yello
w:
Yello
w:
2 sec
0,5 sec
(Green/Yellow)
D
ALI,
Bi-color LED
Test
Green:
Green:
R
ed:
R
ed:
2 sec
0,5 sec
(Green/Red)
Self-contained,
Green:
Green:
Green LED
+7 days
×
×
ODD
EVEN
Indicating LED
6
4 5
3
1 2
8
7
LED
LED
6
4 5
3
1 2
8
7
LED
LED
Indicating LED
Telecommand
Dimensions
Bat
tery Dimensions
(in mm)
Con
version Kit LED Dimensions
Indicating LED messag
es