Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this 

product must be performed by a qualified electrician. This product must be installed in accordance 

with the applicable installation code by a person familiar with the construction and operation of 

the product and hazards involved. 

Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or 

attempting any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Minimum 90°C supply conductors.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Due to sharp edges, handle with care.

Failure to comply with these instructions may result in death, serious bodily injury and property 

damage.

WARNING

DISCLAIMER OF LIABILITY: Eaton assumes no liability for damages or losses of any kind that may arise from the 

improper, careless, or negligent installation, handling or use of this product. 

 

IMPORTANT:

 Read carefully before installing fixture. Retain for future reference. 

NOTICE:

 Fixture may become damaged and/or unstable if not installed properly.

Note:

 Specifications and dimensions subject to change without notice.

Note:

 This fixture should be supported by main runners or other structure that is capable of supporting fixture 

weight of 40 Ibs. 

ATTENTION Receiving Department:

 Note actual fixture description of any shortage or noticeable damage on 

delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be 

filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Wiring Diagrams and Instructions – HCC4, HCC6, HCC8 & 

Commercial LED Rough-In 

Schéma et instructions de câblage – Luminaire DEL à montage sur 

gobetis HCC4, HCC6, HCC8 et commercial 

Diagramas de cableado e instrucciones: HCC4, HCC6, HCC8 y 

Rough-In para LED de uso comercial

Surface Mounts

HCC8S

HCC4W

HCC6S

HCC6W

HCC4S

HCC8W

Wall Mounts

Outer Diameter

Height

HCC4

6-7/8"

10-3/4"

HCC6

8-3/16"

12-1/8"

HCC8

10-1/4"

16"

Summary of Contents for HALO Commercial HCC4

Page 1: ...arise from the improper careless or negligent installation handling or use of this product IMPORTANT Read carefully before installing fixture Retain for future reference NOTICE Fixture may become dama...

Page 2: ...inder top Rotate cylinder clockwise to engage hooks 7 Ensure holes are aligned install Locking screw Wall Mount Cylinders 1 Install wall mounting plate to splice box using splice box hardware provided...

Page 3: ...Rotate side clips 3 into place to securely attach trim assembly to LED engine Figure 7 4 Plug in the luminaire quick disconnect on the module Figure 8 5 In HCC4 and HCC6 cylinders find the green tethe...

Page 4: ...ure using properly sized wire nuts Be careful not to leave any bare conductors outside of the wire nut connectors 3 Connect white to white black to black and green from electrical service on the suppl...

Page 5: ...t riels AVERTISSEMENT EXON RATION DE RESPONSABILIT Eaton n assume aucune responsabilit pour les dommages ou pertes de toute nature pouvant d couler d une installation inappropri e imprudente ou n glig...

Page 6: ...z le fil dans la boite de jonction 6 Ins rez les languettes de la plaque de montage sur le dessus du cylindre Tournez le cylindre dans le sens des aiguilles d une montre pour enclencher les crochets 7...

Page 7: ...ntage et correspondant la surface de montage Garniture 1 Retirez l emballage de protection de la garniture inf rieure Tournez les pinces lat rales 3 vers l ext rieur Figure 5 Retirez l emballage de pr...

Page 8: ...ucheux Raccord lectrique Assurez vous que tous les fils d nud s sont l int rieur des capuchons de connexion 1 Acheminez l alimentation lectrique la boite de jonction sur le cadre d ench ssement pour p...

Page 9: ...e lesiones corporales graves y da os a la propiedad ADVERTENCIA RENUNCIA DE RESPONSABILIDAD Eaton no asume ninguna responsabilidad por da os o p rdidas de ning n tipo que puedan surgir por la instalac...

Page 10: ...e el cableado en la caja de conexiones 6 Inserte las leng etas de la placa de montaje en la parte superior del cilindro Gire el cilindro hacia la derecha para enganchar los ganchos 7 Aseg rese de que...

Page 11: ...sto de silicona alrededor de todo el per metro del brazo de montaje donde se une a la superficie de montaje Borde 1 Retire el borde inferior del embalaje protector Gire los clips laterales 3 hacia afu...

Page 12: ...pelusa Conexi n el ctrica Aseg rese de que no haya cables pelados expuestos por fuera de los conectores de las tuercas para cables 1 Proporcione el servicio el ctrico de acuerdo con el C digo El ctri...

Page 13: ...com LightingWarrantyTerms para conocer nuestros t rminos y condiciones FCC Statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to p...

Reviews: