Installation Guide: EV direct connect and junction box kits
EV DIRECT CONNECT AND JUNCTION BOX KITS
www.eaton.com
EV smart breaker charger operation
QUICKLAG thermal-magnetic breaker
The EV smart breaker charger contains integral solenoid controlled contacts in series with QUICKLAG™
thermal-magnetic breaker. The instructions below describe how to operate the main handle of the EV smart
breaker charger:
• Main handle must be in the ON position to supply power to the load
• When breaker trips, handle will move to the center-tripped position
• To reset breaker, push handle to OFF position, and then to ON position
GFCI test button
Initiates a ground fault self-test. Recommended to perform this test when J1772 connector is plugged into the EV.
EV charger reset button
Resets the EV charger.
EV charger status LEDs
Display status of the EV charger and various fault conditions, if present.
Smart breaker display button
When pressed momentarily, Wi-Fi signal strength is displayed on smart breaker status LEDs. For non-OCPP EV chargers, pushing
this button two times will initiate a manual override of any schedules and will allow for a single charge session. If the LED is
flashing red, double press and hold this button for 15 seconds to clear the fault.
Smart breaker reset button
Reset the Wi-Fi antenna module and regain connectivity or clear any errors that may have occurred during the BlinkUp process.
Smart breaker status LEDs
LEDs show how loaded the circuit is compared to its capacity. The color of the LEDs will range from off indicating no load or too small of
a load detected. Green indicates a low load, yellow indicates a medium load, and red indicates a high load. If the LEDs are flashing, this
indicates that the current exceeds the rating of the smart breaker. When the smart breaker display button is pressed, these LEDs also
show the Wi-Fi signal strength.
BlinkUp status LED
Indicates the status during the BlinkUp process.
Thermal-magnetic breaker handle To manually trip or reset the thermal-magnetic breaker.
Remote contact indicator
Indicates status of secondary contacts (Open: Green / Close: Red ).
Item
Description
GFCI test button
EV charger reset button
EV charger heartbeat LED
BlinkUp receiver/network status amber LED
EV charger
status LEDs
Smart breaker
reset button
Smart breaker
display button
Electronic line
connection
Terminals
(for connection to
loadcenter bus)
Smart breaker
status LEDs
Thermal-magnetic
breaker handle
Remote contacts indicator
Thermal-magnetic pole 1
Thermal-magnetic pole 2
Terminals 1 and 2
(for connection
to field wiring)
Neutral pigtail
(for electronics
module power)
Terminal 4 (for connection to J1772 pilot)
Terminal 3 (for connection to +12 Vdc)
Ground pigtail
Terminal 5
(for connection to ground)