9.  Install the communications base board partially 

into the slots. Make sure the connections for the 

communications modules are facing toward the front of 

the control and to the outside. See 

Figure 5

.

Figure 5 .  Installing the communications base board

10.  Locate the nib on the aluminum support bar (

Figure 6

and the hole in the base circuit board (

Figure 7

).

Figure 6 .  Support bar nib

Figure 7 .  Hole in the base circuit board

11.  Hook the support bar nib into the hole in the base 

circuit board (

Figure 8

) and begin to push the circuit 

board into the slots. While pushing the base circuit 

board in, line up the support bar into the guide grooves 

in the back of the communications module slots 

(

Figure 9

).

Figure 8 .  Hooking the support bar nib into the hole in 

the base circuit board

Summary of Contents for Form 4D Recloser Control

Page 1: ...Form 4D Recloser Control Communications Module Installation Instructions COOPER POWER SERIES Reclosers MN280091EN Effective April 2018 New Issue ...

Page 2: ...URPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liability or other wise fo...

Page 3: ...ITATION OF LIABILITY I SAFETY INFORMATION III Safety instructions iii PRODUCT INFORMATION 1 Introduction 1 Additional information 1 Acceptance and initial inspection 1 Handling and storage 1 Quality standards 1 Description 1 INSTALLATION INSTRUCTIONS 1 Remove existing module 1 Install module 5 ...

Page 4: ...dous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury NOTICE Indicates a potentially hazardous situation which if not avoided may result in equipment dama...

Page 5: ...e use store the kit where the possibility of damage is minimized Quality standards ISO 9001 Certified Quality Management System Description The communications module kit provides the hardware needed to install a communications module or modules into a Form 4D recloser control Table 1 Kit part identification Item Description Qty 1 Communications Module 1 or 2 2 Communications Base Circuit Board 1 3...

Page 6: ...panel opening Three 3 Retaining Bar Nuts Module Swing Panel Ground Link Nut Figure 1 Loosen retaining bar nuts and tilt module back Ground Link Nut Figure 2 Loosen for removal or align for installation with ground link Figure 3 Remove screws shown to open the cover of the communications module slots Figure 4 Communications module slots with cover removed ...

Page 7: ...ons base board 10 Locate the nib on the aluminum support bar Figure 6 and the hole in the base circuit board Figure 7 Figure 6 Support bar nib Figure 7 Hole in the base circuit board 11 Hook the support bar nib into the hole in the base circuit board Figure 8 and begin to push the circuit board into the slots While pushing the base circuit board in line up the support bar into the guide grooves in...

Page 8: ...e support bar and secure with the provided screw See Figure 10 Figure 10 Support bar fully inserted and secured with a screw 13 Install the communications module into the top communications module slot Com Port 1 and secure with two of the 6 32 screws supplied with the kit See Figure 11 and Figure 12 Figure 11 Inserting communication module into Com Port 1 communications slot Figure 12 Communicati...

Page 9: ...ith the lower edge of the swing panel 2 Position the ground link on the swing panel to line up with the ground lug on the module as it moves into position Figure 2 3 Lift up on the module until the ground link slides into place and continue lifting up until the module is firmly back into the swing panel 4 Press into place as necessary 5 Slide the retaining bar down all the way over the module s al...

Page 10: ...6 INSTALLATION INSTRUCTIONS MN280091EN April 2018 Form 4D Recloser Control Communications Module This page is intentionally left blank ...

Page 11: ...7 INSTALLATION INSTRUCTIONS MN280091EN April 2018 Form 4D Recloser Control Communications Module This page is intentionally left blank ...

Page 12: ...ates Eaton com cooperpowerseries 2018 Eaton All Rights Reserved Printed in USA Publication No MN280091EN April 2018 KA20480756 Rev 0 Eaton is a registered trademark All trademarks are property of their respective owners For Eaton s Cooper Power series product information call 1 877 277 4636 or visit www eaton com cooperpowerseries SAFETY FOR LIFE ...

Reviews: