12 Configuration
ESR5-NV3-300
12/19 MN049006EN
www.eaton.com
17
12 Configuration
12.1 Setting the delay time
Use the rotary switch and DIP switch on the device to set the delay time in
24
increments from 0.2
s to 300
s.
The 24 increments are the result of four periods (DIP switch), each with
six delay times (rotary switch), see figure.
Configuring the safety relay
To configure the safety relay, proceed as follows:
▶
Set a time period using the DIP switches.
▶
Set the desired delay time with the rotary switch.
Figure 12: Configuration of the delay time (in seconds)
1
2
3
4
5
6
0,2
0,4
0,6
0,8
1,0
1,2
0,8
1,6
2,4
3,2
4,0
4,8
6,4
12,8
19,2
25,0
32,0
38,0
50
100
150
200
250
300
WARNING
Danger due to incorrect setting!
An incorrect configuration can result in dangerous machine or
system states.
Check the configuration before starting up for the first time.
1
6
3
4
5
2
B
A
B
A
B
A
B
A
Summary of Contents for ESR5-NV3-300
Page 1: ...Manual ESR5 NV3 300 Safety relay 12 19 MN049006EN...
Page 4: ......