INTRODUCTION
Your 5330X-400 is an UP counting totalizer with a high-
contrast eight-digit LCD display. The front-panel reset key
can be disabled. A remote-reset terminal is provided.
APPLICATIONS
This totalizer is intended for simple totalizing applications.
One count input pulse per item is necessary. The only
decisions to be made are:
1.
Do you use the high or low speed input?
2.
Do you want the front panel reset button active?
OPERATION
The totalizer display has lead-zero blanking. No decimal
point is available.
Count Inputs
Separate contact and solid state count inputs are provided.
The solid state input (terminal 3) requires a current-sourc-
ing sensor and can count up to 10 kHz. Inputs into this
terminal are counted on the positive-going edge.
8-digit LCD
Display
FRONT VIEW
Reset
button
Plastic
front panel
sealed to
meet
NEMA 4X
REAR VIEW
Solid State input
Contact input
Reset
Ground
Durant
®
Front Panel
Reset Key
Enable
5 Enable/R
5 Enable/R
RST 4
IN A 3
IN B 2
GND 1
6 DC Common
7 +10-30VDC
Count occurs on this edge of the pulse
(Voltage applied to terminal)
Terminal 3 is pulled down to common. When a sensor
output supplies voltage to this terminal, one count is regis-
tered on the display. The sourcing signal must supply at
least +1.0VDC but no more than +28VDC.
Note: When a sourcing signal is applied to terminal 3, a
power assist feature of the Courier extends the life of the
battery.
Terminal 2 is the low-speed, current-sinking count input
designed to be used with a contact closure to ground. It has
a maximum count speed of 20 Hz. Inputs into this terminal
are counted on the negative-going edge.
Input realized
on this edge
of the pulse
Contact Closes
Contact Opens
Terminal 2 is pulled up to +3VDC. When a contact closes,
pulling the voltage down to .4 VDC or less, one count is
registered.
RUN MODE
Screens
The totalizer screen is the only screen available on this
model.
Front Panel Reset Enable
The front-panel reset button comes disabled from the
factory. To enable the button, install a jumper wire from
terminal 5 to ground, terminal 1.
Note: The reset terminal on the rear panel is still active when
the front reset button is disabled.
PROGRAM MODE
There is no program mode for this model.
2
MOUNTING
Durant
Install mounting clip
Gasket Installed?
Durant
®
2.677"(68mm)
1.299"
(33mm)
Recommended
Panel Cutout
5 Enable/R
5 Enable/R
RST 4
IN A 3
IN B 2
GND 1
6 DC Common
7 +10-30VDC