47523, Revision 4
MAINTENANCE
To service the unit: Isolate it from the process air and electric supply
by using proper lockout tagout procedures. Depressurize unit by
opening purge valve and deenergize all sources of power.
•
Disconnect all remote airlines running to the assembly, marking
all airlines before removing. Remove the center shaft
connection bolt and the four bolts holding the twin assembly to
the lid. Remove the twin assembly.
•
Remove the 8 bolts from the lid. Tighten packing compression
wheel. Remove lid assembly with cleaning disc attached.
•
Inspect cleaning disc for excessive wear. If replacement is
required, refer to instructions included with replacement disc.
•
Remove element by first removing compressor assembly and
upper “O” ring. Remove element using attached handles.
Inspect element for damage and plugging. Clean or replace as
needed. Remove lower “O” ring and clean.
•
To reassemble, flush housing removing all dirt and
contaminants. Clean and inspect all “O” rings for damage,
replace as needed. Place lower “O” ring in bottom of the
housing making sure it lays flat and is centered on the ID of the
housing. Replace clean element in the housing with the
handles up. Place the upper element “O” ring on top of the
element insuring that it lays flat and is centered on the ID of the
housing. Place the clean compressor assembly on top of the
element and align it so the bars are not obstructing the inlet
assembly.
•
Place the lid “O” ring on the upper body flange, again, flat and
centered. Replace lid and cleaning disc assembly by
compressing the cleaning disc with the compression pliers
supplied with the unit. Lid may need to be raised to make room
for pliers. Insert the cleaning disc in the element and release
the pliers. Seat the lid on the unit. Double-check the
placement of the lid “O” ring, replace the lid bolts and tighten.
•
Replace the twin assembly insuring that the safety device is in
place and operating.
•
Loosen the packing compression wheel to proper specification.
•
Reconnect the airlines.
•
Place the system back on line using proper plant procedures.
•
Test the safety device by tripping it while the unit is in motion.
The unit should stop moving. If this does not work, lock the unit
out and contact Ronningen-Petter customer service. If unit
operates correctly, reset the safety switch and put the unit back
online.
For maintenance of other items such as lid seals, actuators, and
valves, see instructions supplied with repair kits.
EATON Filtration, LLC
9151 Shaver Road
Portage, Michigan 49024-6798 USA
Phone (Worldwide) +1 269 323 1313
Phone (U.S.) +1 800 656 3344
Fax +1 269 323 2403
Email [email protected]
www.filtration.eaton.com
ELEMENT
SLOTTED ELEMENT SIZES
PERFORATED ELEMENT SIZES
47341
0.024"
SEE ELEMENT O-RING
CHART
SEE LID O-RING
CHART
41009
42756
45475
40626
SEE ELEMENT O-RING CHART
SEE ELEMENT CHARTS
P-10336-BRZ
42630
42909
31328
P-30886-SS6
P-41289-SS6
SEE DISC REPAIR
KIT CHARTS
SEE DISC ASSEMBLY
CHARTS
TEFLON
VITON
42622
42624
42626
42628
MAT'L
O-RINGS
LID
42661
47330
0.250"
0.125"
RETENTION
P/N
42650
47331
42653
0.062"
0.045"
0.030"
DEFINED PORE SIZES
P/N
63050
63053
63055
63054
63051
63052
63076
63048
63049
63089
63090
P/N
RETENTION
0.006"
0.024"
0.030"
0.045"
0.009"
0.015"
0.001"
0.002"
0.003"
0.004"
0.0015"
42635
0.004"
42652
42637
42638
47332
42636
0.008"
0.015"
0.009"
0.007"
0.006"
0.0006"
40668
42634
42633
42632
42631
0.0015"
0.003"
0.002"
0.001"
610
6250
3125
(MICRON)
1550
1125
750
(MICRON)
100
200
380
230
175
150
38
75
50
25
15
RETENTION
(MICRON)
1140
760
610
380
230
150
100
75
50
38
25
URETHANE
NYLON
MAT'L
KYNAR
UHMWPE
TEFLON
CLEANING DISC (WIDE EDGE)
40703
40707
47141
ASSY
40632
40634
40633
47307
47308
40712
REP. KIT
31338
NON-STOCK ITEMS:
ALLOW 6-8 WEEKS
FOR DELIVERY.
BUN
EPT
42623
42621
42627
42625
45422
45421
*NIT
* WHITE, FDA APPROVED
FOOD GRADE.
TEF / SOFT
45483