background image

TD 17530A

Page 1

Effective 5/98

SECTION 1: INTRODUCTION/QUICK START

1-1  PRELIMINARY COMMENTS AND SAFETY 
PRECAUTIONS

This technical document is intended to cover most
aspects associated with the installation, application,
operation and maintenance of the IQ Analyzer. It is
provided as a guide for authorized and qualified
personnel only in the selection and application of the IQ
Analyzer. Please refer to the specific WARNING and
CAUTION in Section 1-1.2 before proceeding. If further
information is required by the purchaser regarding a
particular installation, application or maintenance
activity, a Cutler-Hammer representative should be
contacted.

1-1.1  WARRANTY AND LIABILITY 
INFORMATION

NO WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING WARRANTIES OF FITNESS FOR A
PARTICULAR PURPOSE OF MERCHANTABILITY, OR
WARRANTIES ARISING FROM COURSE OF
DEALING OR USAGE OF TRADE, ARE MADE
REGARDING THE INFORMATION,
RECOMMENDATIONS AND DESCRIPTIONS
CONTAINED HEREIN. In no event will Cutler-Hammer
be responsible to the purchaser or user in contract, in
tort (including negligence), strict liability or otherwise for
any special, indirect, incidental or consequential
damage or loss whatsoever, including but not limited to
damage or loss of use of equipment, plant or power
system, cost of capital, loss of power, additional
expenses in the use of existing power facilities, or
claims against the purchaser or user by its customers
resulting from the use of the information and
descriptions contained herein.

1-1.2  SAFETY PRECAUTIONS

All safety codes, safety standards and/or regulations
must be strictly observed in the installation, operation
and maintenance of this device.

THE WARNINGS AND CAUTIONS INCLUDED AS
PART OF THE PROCEDURAL STEPS IN THIS
DOCUMENT ARE FOR PERSONNEL SAFETY AND
PROTECTION OF EQUIPMENT FROM DAMAGE. AN
EXAMPLE OF A TYPICAL WARNING LABEL

HEADING IS SHOWN ABOVE IN REVERSE TYPE TO
FAMILIARIZE PERSONNEL WITH THE STYLE OF
PRESENTATION. THIS WILL HELP TO INSURE
THAT PERSONNEL ARE ALERT TO WARNINGS,
WHICH MAY APPEAR THROUGHOUT THE
DOCUMENT. IN ADDITION, CAUTIONS ARE ALL
UPPER CASE AND BOLDFACE AS SHOWN BELOW.

COMPLETELY READ AND UNDERSTAND THE
MATERIAL PRESENTED IN THIS DOCUMENT
BEFORE ATTEMPTING INSTALLATION,OPERATION
OR APPLICATION OF THE EQUIPMENT. IN
ADDITION, ONLY QUALIFIED PERSONS SHOULD
BE PERMITTED TO PERFORM ANY WORK
ASSOCIATED WITH THE EQUIPMENT. ANY WIRING
INSTRUCTIONS PRESENTED IN THIS DOCUMENT
MUST BE FOLLOWED PRECISELY. FAILURE TO DO
SO COULD CAUSE PERMANENT EQUIPMENT
DAMAGE.

1-1.3  FACTORY CORRESPONDENCE

Contact the Advanced Product Support Center at 1-800-
809-2772 for any questions regarding the operation or
troubleshooting of the IQ Analyzer.

1-2  PRODUCT OVERVIEW

The IQ Analyzer is a micro-processor based electrical
distribution system monitor. It provides extensive
metering, power quality analysis, remote input
monitoring, control relaying, analog input/outputs, and
communications capabilities. IQ Analyzer is a compact,
panel mounted device. It mounts in less than 7 by 11
inches of space and provides the functionality of dozens
of individual meters, relays and recorders (Figure 1-1).

IQ Analyzer:

• Complies with rigid ANSI C12.16 Class 10 revenue

meter accuracy standard

• Provides true rms readings through the 50th harmonic

• Accurately measures nonsinusoidal waveforms up to

a 3.0 crest factor

• Displays even and odd multiples of fundamental

current and voltage through 50th harmonic

• Displays both magnitude and phase angle of the

harmonics 

• Monitors neutral and ground conductors in addition to

3 phases

!

CAUTION

!

WARNING

Summary of Contents for Cutler-Hammer TD 17530A

Page 1: ...TD 17530A Effective 5 98 Cutler Hammer Instructions for Installation Operation and Maintenance of Cutler Hammer IQ Analyzer Electrical Distribution System Monitor...

Page 2: ...TH SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING ANY UNPACKING ASSEMBLY OPERATION OR MAINTENANCE OF THE PRODUCT INSTALLATION OR MAINTENANCE SHOULD...

Page 3: ...RE DESCRIPTION 2 1 General 6 2 2 Operator Panel 6 2 3 Rear Access Area 7 2 3 1 Back of Chassis 7 2 3 2 Left Rear of Chassis 8 2 3 3 Right Rear of Chassis 8 2 4 External Hardware 9 2 4 1 Current Transf...

Page 4: ...mary Rating 50 5 5 7 Programming Options 51 5 5 8 Power Energy Options 51 5 5 9 Date and Time 51 5 5 10 Change Password 52 5 6 Inputs Outputs 52 5 6 1 Discrete Contact Inputs 52 5 6 2 Analog Input 52...

Page 5: ...66 5 8 3 Voltage Disturbance Analysis 66 5 8 4 IMPACC Enhanced Graphics 66 5 8 5 IMPACC Connectivity 66 5 9 IQ Analyzer 6200 Series Graphic Displays 67 5 10 Reset Mode 67 SECTION 6 PROGRAMMING 6 1 Int...

Page 6: ...P SETTINGS SHEETS General Setup Settings 93 Analog Input Settings 94 Analog Output Settings 95 Discrete Input Settings 96 Event Trigger Settings 98 Relay Output Settings 106 Demand Settings 111 Displa...

Page 7: ...etwork Wiring Diagram 25 4 7 IQ Analyzer with Self Powered Three Phase Power Module Rear View 27 4 8 IQ Analyzer with Separate Source Power Module Rear View 28 4 9 thru 4 34 Wiring Diagrams 29 42 5 1...

Page 8: ...evel Screen Showing Password Entry Field 70 6 2 Programming Example Flow Chart 74 81 6 3 Program Mode Top Level Menu 81 6 4 General Setup Screens Tree 82 6 5 Analog Inputs Screens Tree 83 6 6 Analog O...

Page 9: ...UTIONS INCLUDED AS PART OF THE PROCEDURAL STEPS IN THIS DOCUMENT ARE FOR PERSONNEL SAFETY AND PROTECTION OF EQUIPMENT FROM DAMAGE AN EXAMPLE OF A TYPICAL WARNING LABEL HEADING IS SHOWN ABOVE IN REVERS...

Page 10: ...nalyzer is comprised of the IQA 6000 Series and IQA 6200 Series of system monitors The IQA 6000 Series and IQA 6200 Series are similar in the features offered except that graphic and transient trigger...

Page 11: ...re furnished to share data with PLCs and control systems and to actuate alarms and control relays Terminals are captive clamp type and finger safe Figure 2 2 With the communications option IQ Analyzer...

Page 12: ...he Screens Trees which diagram the categories of settings 7 Troubleshooting and Maintenance Provides a troubleshooting matrix of symptoms probable causes and solutions Also described are the steps for...

Page 13: ...ge IQFLANGE 5743B02G01 IQ Analyzer 36 inch extension cable IQACABLE 2107A55G02 IQ Analyzer 45 inch extension cable IQA45CABLE 2107A55G03 Self powered three phase power module only IQA3PPM 8793C15G01 S...