15
AC WIRING/CONTACT INPUT WIRING
AC Power Input
(AC Models Only)
Neutral
Hot
AC Power In
Electrical
Ground
Terminal 4 (Ground) and terminals
2 and 3 (Com) are internally
connected.
Terminal 4 (Ground) and terminals
2 and 3 (Com) are internally
connected.
10-15 VDC Input
+
DC Power Input
(DC Models Only)
Check part number on counter
label to verify correct voltage
rating.
57601-40X: 115 VAC
57602-40X: 230 VAC
Check part number on counter
label to verify correct voltage
rating.
57600-40X: 10-15 VDC
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
To prevent multiple counts, use one
of the contact count modes. See
programming diagram.
All dip switches OFF.
Push button
limit switch,
relay contact,
etc.
Contact Count Input
1
12
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
Dotted lines indicate which
inputs may be wired in this
manner. Typically a separate
sensor is used for each input.
Control inputs (terminals
15-18) may be wired in the
same manner.
-
Use slow blow fuses for all voltages.
Use 1/2 amp slow blow fuse.
(Does not include external
transducer load.)
Fuse Size
AC Power In
115 V, 60 Hz
115 V, 50 Hz
230 V, 60 Hz
230 V, 50 Hz
U.S.
1/8 amp
1/4 amp
1/16 amp
1/8 amp
European
T125 mA, 250 V
T250 mA, 250 V
T 60 mA, 250 V
T125 mA, 250 V