background image

9

Operation

Initial Operation

Protect the digital level 
against moisture and direct 

sun light.

Do not subject the digital 
level to extreme tempera-

tures or variations in temperature. 

As an ex-

ample, do not leave it in vehicles for a long 
time. In case of large variations in temperature, 
allow the digital level to adjust to the ambient 
temperature before putting it into operation. In 
case of extreme temperatures or variations in 
temperature, the accuracy of the digital level 
can be impaired.

The contact surfaces and 
contact edges of the digital 

level must be clean. Protect the digital level 
against impact and shock.

 Debris particles or 

deformations can lead to faulty measurements.

Avoid heavy impact to or 
dropping down of the digi-

tal level.

 After severe exterior effects to the 

digital level, it is recommended to carry out an 
accuracy check (see “Checking the Measuring 
Accuracy”) each time before continuing to 
work.

Switching On and Off

Press the 

“ON/OFF”

 switch 

9

 to switch the 

digital level on or off.

If no button on the digital level is pressed for 
approx. 30 mins or the grade of the digital level 
is not changed by more than 1.5°, then the 
grade measurement and the display are auto-
matically switched off to save the battery.

Checking the Measuring Accuracy 

(see figure B)

Check the accuracy of the digital level each 
time before using, after extreme temperature 
changes as well as after heavy jolts or impact.

Before measuring angles <45°, the accuracy 
check should take place on a level and horizon-
tal surface; before measuring angles >45°, on a 
level and vertical surface.

Switch the digital level on and place it on the 
horizontal or vertical surface.

Wait for 10s and write down the measured 
value.

Rotate the digital level (as shown in the figure) 
by 180° around its vertical axis. Wait again for 
10s and write down the second measured vale.

Calibrate the digital level only when the dif-
ference between both reading values is great-
er than 0.1°.

Calibrate the digital level in the position (ver-
tical or horizontal), in which the difference of 
the measured values has been determined.

Calibration for Horizontal Surfaces (see 

figure C)

The horizontal surface used to calibrate the 
tool cannot slope more than 5°.  If the slope is 
greater than 5°, the calibration is discontinued 
and 

“---”

 will display.  

c

  Switch the digital level on and place it onto 

the horizontal surface so that the spirit lev-
el 

1

 faces upward and the display 

5

 faces 

you. Wait for 10s.

d

  Then press the 

“Cal”

 calibration button 

10 

until 

“CAL1”

 appears on the display. Then 

the measuring value will flash on the dis-
play.

e

  Turn the digital level 180° around the ver-

tical axis so that the spirit level still faces 
upward, but the display 

5

 faces away from 

you. Wait for 10s.

f

  Then press the 

“Cal”

 calibration button 

10 

again. 

“CAL2”

 will be shown on the display. 

Then the measuring value (no longer flash-
ing) will appear on the display. The digital 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 3 601 K76 710

Page 1: ...ee for Consumer Information and Service Locations Pour obtenir des informations et les adresses de nos centres de service après vente appelez ce numéro gratuit Llame gratis para obtener información para el consumidor y ubicaciones de servicio IMPORTANT Read Before Using IMPORTANT Lire avant usage IMPORTANTE Leer antes de usar www com information itm com 1 800 561 8187 ...

Page 2: ...2 a b c e b f g a c 1 7 8 9 12 10 11 3 2 4 5 6 GIM 60 GIM 120 d IN FT A IN FT IN FT 1 2 I N F T IN FT I N F T 0 0 0 IN FT 90 0 0 IN FT www com information itm com 1 800 561 8187 ...

Page 3: ...3 D 0 1 D D 0 1 D 10 s 180 10 s D 0 1 C D 0 1 10 s D 180 10 s ON B www com information itm com 1 800 561 8187 ...

Page 4: ...4 Calibrate 180 10 s Calibrate 180 10 s Calibrate 180 10 s Calibrate 10 s ON C www com information itm com 1 800 561 8187 ...

Page 5: ...5 Calibrate 10 s 180 Calibrate 180 10 s Calibrate 10 s 180 Calibrate 10 s ON D www com information itm com 1 800 561 8187 ...

Page 6: ...reach of children Remove batteries if the device will not be used for several months Maintenance DO NOT use this digital level for any purpose other than those outlined in this manual This could result in serious injury ALWAYS use only the accessories that are recommended by the manufacturer of your digital level Use of accessories that have been designed for use with other digital levels could re...

Page 7: ...M 60 GIM 120 Article number 3 601 K76 710 3 601 K76 810 Dimensions Length Width Height 24 in 608 mm 1 06 in 27 mm 2 3 in 59 mm 49 2 in 1250 mm 1 06 in 27 mm 2 3 in 59 mm Measuring range 0 360 4 x 90 0 360 4 x 90 Measuring accuracy 0 90 1 89 0 05 0 2 0 05 0 2 Operating temperature 14 F 122 F 10 C 50 C 14 F 122 F 10 C 50 C Storage temperature 4 F 158 F 20 C 70 C 4 F 158 F 20 C 70 C Alkaline Batterie...

Page 8: ...or The battery indicator f always displays the cur rent battery status The battery is over 90 full The battery is between 60 and 90 full The battery is between 30 and 60 full The battery is between 10 and 30 full The empty battery indicator flashes The battery level is under 10 Once the bat tery indicator begins flashing you can measure for approximately another 15 20 minutes until the tool shuts do...

Page 9: ...e changes as well as after heavy jolts or impact Before measuring angles 45 the accuracy check should take place on a level and horizon tal surface before measuring angles 45 on a level and vertical surface Switch the digital level on and place it on the horizontal or vertical surface Wait for 10s and write down the measured value Rotate the digital level as shown in the figure by 180 around its ve...

Page 10: ...the measuring value will flash on the dis play e Turn the digital level 180 around the ver tical axis so that the spirit level still faces upward but the display 5 faces away from you Wait for 10s f Then press the Cal calibration button 10 again CAL2 will be shown on the display Then the measuring value no longer flash ing will appear on the display The digital level has now been recalibrated for th...

Page 11: ...11 again to return stored measurement Indicator H is shown flashing on the display Long press the Hold Copy button 11 to store a new value To delete a Hold value press the ON OFF button 9 displayed in indicator b c The current measur ing value is automatically converted The unit of measure setting is retained when switching the digital level on or off Switching the Audio Signal On Off The audio signa...

Page 12: ... 1 year from date of purchase Bosch will extend warranty coverage to two 2 years when you register your product within eight 8 weeks after date of purchase Register on line If you choose not to register your product a one 1 year limited warranty will apply to your product 30 Day Money Back Refund or Replacement If you are not completely satisfied with the per formance of your laser and measuring t...

Page 13: ...IMPLIED WAR RANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAM AGES INCLUDING BUT NOT LIMITED TO LIA BILITY FOR LOSS OF PROFITS ARISING FROM THE SALE OR USE OF THIS PRODUCT SOME STATES IN THE U S AND SOME CANADIAN PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES SO THE ABOVE L...

Reviews: