background image

©

Copyright Eaton Corp., 2006. All rights reserved.

QRV 9100

Installation, Operation
and Maintenance of
Airflex

®

 Quick Release 

Valve

Forward this manual to the person responsible 
for Installation, Operation and Maintenance of 
the product described herein. Without access to 
this information, faulty Installation, Operation or 
Maintenance may result in personal injury or 
equipment damage.

Use Only Genuine 

Airflex

®

 Replacement Parts.

The Airfiex Division of Eaton Corporation recommends 
the use of genuine Airfiex replacement parts. The use of 
non-genuine Airflex replacement parts could result in 
substandard product performance, and may void your 
Eaton warranty. For optimum performance, contact
Airflex:

I

n the U.S.A. and Canada:

(800) 233-5926

Outside the U.S.A. & Canada: 

(216) 281-2211

Internet: 

www.airflex.com

October, 1987

(Revised : November, 2006

)

203977

Note:

 This manual pertains to the AIRFLEX

DIAPHRAGM OPERATED QUICK RELEASE 
VAVLE which is identified by its silver housing. If 
your valve housing is anodized green, service it 
according to manual 

QRV 9090

 or replace the entire 

valve with the diaphragm style.

Summary of Contents for 145406

Page 1: ...f Eaton Corporation recommends the use of genuine Airfiex replacement parts The use of non genuine Airflex replacement parts could result in substandard product performance and may void your Eaton war...

Page 2: ...Inlet Pipe Thread Muffler DT 3 4 145141 w Metal Sleeve Pipe Adapter DL BR w Metal Sleeve 1 4 Pipe Adapter DM 1 146506 Diaphragm End Cap Kit DP DP Diaphragm Muffler End Cap Kit DQ DQ 1 4 NPT adapter f...

Page 3: ...exhaust port at the chamber rather than exhausting through long supply lines and con trol components The function they perform is especially important in high speed cycling equipment They prevent slu...

Page 4: ...ir from air lines and disconnect all electrical power 2 1 Air Piping 2 1 1 For fastest response time use an inlet pipe size equal to or larger than the quick release valve size Minimize the length of...

Page 5: ...nut sufficiently to produce an air seal but not more than the value given in Table 4 2 2 4 If a muffler is to be used install per the following instructions Loctite must be used where called for in th...

Page 6: ...air from the air lines and dis connect all electrical power in order to pre vent personal injury and or equipment damage 3 1 1 If the quick release valve exhaust port is positioned downward it will b...

Page 7: ...ent the muffler if applicable may be installed at this time otherwise install the quick release valve and muffler onto the equipment per the Installation section of this manual When installing the muf...

Page 8: ...defective part or parts or by making avail able at Eaton s plant a repaired or replacement part This warranty does not extend to normal wear parts or components of the Product such as friction materi...