Polar Compressor Rotary Screw Compressors
Revision July.2015
www.eatoncompressor .com
877.283.7614
25 |
P a g e
PLC screen. This means the pump is
operating and the compressor is
building pressure.
5.
Monitor display panel for normal
readings such as amp draw and
voltage. Push OFF button if there are
any abnormal sounds vibration or oil
leakage.
6.
Check that oil exhaust temperature is
maintained between 160˚ - 190˚ F
(70˚ - 88˚ C). Cooling fan cycles as
needed to cool oil temperature.
7.
After OFF button is pressed, the
motor continues to run for approx.
10-15 seconds and blow-down valve
automatically discharges pressure
from air/oil separator tank. This is
to prevent the air compressor from
stopping under heavy-load.
8.
Record these instrument readings on
a regular basis and retain for future
reference:
Voltage
Current
Air pressure
Air exhaust temperature
Oil level
Maintenance parameter
Power Outages
Once power is restored
after a power outage the controls will show a
“Power Fault” error. Press the Enter button
to reset and restart the compressor.
Storage
1.
If the machine is stopped for over
three weeks:
a)
Wrap electrical equipment such
as the control panel with plastic
or oil paper to avoid
condensation.
b)
Completely drain water in the oil
cooler, the back cooler and the
oil/air separator tank.
c)
Make sure any unsafe conditions
are clearly stated or repaired.
2.
If the machine is not run for more
than
two months:
a)
Seal all ports to prevent moisture
or dust accumulation.
b)
Wrap safety valve & control
panel with oil paper or an
equivalent to avoid rust.
c)
Replace lubricating oil then run
machine for 30 minutes. Drain
condensed water in the oil/air
separator tank and the oil cooler
2-3 days later.
d)
Move machine to a clean, dry
place.
Restarting Procedure
1.
Remove any wrappings from system
components.
2.
Ensure electric motor is properly
insulated.
3.
Perform initial checks then follow
procedures for start up.
Maintenance
Safety Steps
To avoid shock and
serious personal injury,
disconnect, tag and lock
out power source then
release all pressure from
the system before attempting to
install, service, relocate or perform
ANY maintenance.
To avoid serious personal
injury, when performing
service in any enclosure
large enough to hold a
man, inform others then
be sure to tag and keep open any
access doors. Before closing and
latching access doors, make sure
all
persons are
clear from
enclosure.