Operation as following:
a) Cut off the power, drain the water from the tank and dry the water on the
surface of the atomizer.
b) Unscrew the ring with the lock piece, remove the old ceramic disc, and keep
the atomizer chamber clean.
c) When install the new ceramic disc front face up, and reverse side back down.
Then tighten the pressure ring.
Special tips:
When the water level 0.1-0.5cm higher than the atomizer’s sensor,
the atomizer in the best working status. If the water level is too high or too low,
the fog outlet capacity will be affected.
(
Remark
:
To avoid the float displaced in transportation
,
please adjust the water
level when the first time using.
)
5. Regular failure and failure elimination
Fault symptom
Reason
Remove method
Not working
a) No Power
b) Fuse blown
c) The power switch is not on
d) Humidity over the settled
a) Check the circuit, power
restoration
b) Replace the fuse
c) Turn on the power switch
No water adding
a) No water in the water supply
pipe
b) The water float is blocked
c) The water supply pressure is
not enough
a) Check the water supply
circuit
b) Remove the foreign matter in
the float
c) The pressure must reach
5KG.
Don’t stop when
adding water
a) The water float is displaced
b) There is foreign matter in the
a) Adjust it to the correct
position