background image

Installation Manual & Owner’s Guide

Summary of Contents for RevitaLife

Page 1: ...Installation Manual Owner s Guide ...

Page 2: ...fe Works 2 Unpacking Inspection 3 Specifications 3 Contents 3 Installation 4 9 Start Up Instructions 10 Cartridge Replacement 10 Annual Maintenance Recommendations 11 Limited Warranty 12 RevitaLife Installation Manual Owner s Guide ...

Page 3: ... Remineralizing Filter Raises pH and adds beneficial minerals back to water The water driven permeate pump boosts pressure and directs the water into the compact 3 gallon storage tank D Final Polishing Filter High quality activated carbon provides a final filtration step on the way to the faucet A B D C E Scan QR Code to Watch Video How RevitaLife Drinking Water System Works Benefits of EasyWater ...

Page 4: ...kaged separately Water hardness above 10 gpg requires installation of EasyWater No Salt Conditioner Model RL5010 Min Incoming Water Pressure 30 psi Max Incoming Water Pressure 100 psi Hardness less than 10 gpg Maximum Iron 0 2 ppm Maximum H2 S 0 2 ppm Maximum Manganese 0 05 ppm Maximum TDS 2000 ppm Turbidity Cloudy Water 1 0 ntu Unpacking Inspection Be sure to inspect the entire shipment immediate...

Page 5: ...tric variable speed drill PRODUCT DIMENSIONS DRILL OR PUNCH A FAUCET HOLE IN SINK OR COUNTERTOP Using a 11 4 hole saw bit or knock out punch create a hole for the faucet in sink or countertop Different sink or countertop materials require different tools and methods for punching or drilling a hole Use proper tools and follow your sink or countertop manufacturer s instructions to prevent damage Eas...

Page 6: ...hrough the hole in sink Ensure that the rubber gasket is uniformly positioned between the base and sink 4 Align faucet base with handle on right side and base sitting on top of sink Turn the handle down towards you to the on position to reveal the tightening screw located where the spout will be inserted Using a Phillips head screwdriver turn the screw clockwise until the toggle bolt secures the f...

Page 7: ...t A Valve to the inlet of the reverse osmosis module will be cut to length and attached later in the installation REVITALIFE MODULE MOUNTING Determine the best location for the RO wall module to be mounted to allow for future cartridge changes and system maintenance If installing under a sink be sure the mounting screws are at least 19 from the bottom of the cabinet to allow for changing cartridge...

Page 8: ...ive backed foam gasket to the inside of the semicircle bracket with opening aligning holes 2 Drill a hole through the sink s drain pipe at least 1 above the connecting nut of the P trap be sure to allow for future removal of the P trap Place the drain saddle around the drain pipe positioning the drain saddle over the drilled hole in the pipe To ensure proper alignment insert a screwdriver through ...

Page 9: ...k line from permeate pump output to x 3 8 fitting drain saddle IF FAUCET AIR GAP IS REQUIRED 1 The black line from permeate pump output will connect to faucet air gap inlet 2 The black 3 8 line from faucet outlet will connect to drain saddle If you opt to cut tubing prior to making connections ensure tubing is cut at a 90 angle Improper cutting will increase risk of leaks Adapt A Valve Faucet Conn...

Page 10: ...4 Follow steps 2 and 3 for each cartridge 5 Turn on water supply line and check for leaks 6 Attach face plate to the wall module OPTIONAL REFRIGERATOR KIT INSTALLATION NOTE A refrigerator kit can be ordered by contacting EasyWater 1 Tee off from the line running from the RO unit to the faucet 2 It is recommended to install a shutoff valve on the line running from the line in Step 1 to the refriger...

Page 11: ... has filled open the faucet and allow water to run until the tank empties and water flow slows to a trickle Carbon fines or slightly grayish water may be present Flush the tank in this manner 3 times You only need to flush the tank during initial installation or cartridge replacement The A B C and D cartridges should be changed annually The reverse osmosis membrane E should be changed every two ye...

Page 12: ...cet Repeat Step 7 a second time TANK AIR PRESSURE 1 Turn off the incoming water supply at the Adapt A Valve 2 Open the faucet allow tank to empty then close faucet 3 Check the pressure in the tank using a tire pressure gauge 4 Once emptied the tank pressure should be between 5 7 psi Add air if necessary by using an air compressor Do not overfill 5 Turn on the water supply at the Adapt A Valve PROC...

Page 13: ...regular parts and service charges will apply We assume no warranty liability in connection with this System other than specified herein This warranty is in lieu of all other warranties express or implied including warranties of fitness for a particular purpose We do not authorize any person or representative to assume for us any other obligations on the sale of this filter Should a defect or malfu...

Reviews: