background image

EN 

Instructions

Customer Service / Importer:

DS Produkte GmbH, Am Heisterbusch 1, 19258 Gallin, Germany • 

 

+49 38851 314650 *)

*) Calls to German landlines are subject to charges. The cost varies depending on the service provider.

All rights reserved.

6

Model designation(s): TS-20143

Speci

fi

 cation

Symbol

Value

Unit

Speci

fi

 cation

Unit

Heating output

Only in the case of electric storage local space heat-
ers: Method for controlling the heat supply (please 
select one option)

Rated heat output

P

nom

0.500

kW

manual control of the heat supply with 
an integrated thermostat

[yes / no]

Minimum heat supply 
(guide value)

P

min

0.465

kW

manual control of the heat supply with 
feedback of the room temperature 
and / or ambient temperature

[yes / no]

Maximum continuous 
heat supply

P

max,c

0.500

kW

electronic control of the heat supply with 
feedback of the room temperature 
and / or ambient temperature

[yes / no]

Auxiliary energy 
consumption

fan-driven heat output

[yes / no]

At rated heat output

el

max

0.515

kW

Type of heat output /  room temperature control (please 
select one option)

At minimum heat output

el

min

0.450

kW

single-setting heat output, no room 
temperature control

[yes / no]

In standby

el

SB

0.001

kW

two or more manual settings, no room 
temperature control

[yes / no]

room temperature control with mechani-
cal thermostat

[yes / no]

with electronic room temperature control

[yes / no]

electronic room temperature control and 
time-of-day regulation

[yes / no]

electronic room temperature control and 
day-of-week regulation

[yes / no]

Other control options (multiple selection possible)

room temperature control with occu-
pancy sensor

[yes / no]

room temperature control with open-
window detection

[yes / no]

with remote control option

[yes / no]

with adaptive control of heating start

[yes / no]

with operating time limit

[yes / no]

with black bulb sensor

[yes / no]

Contact details

DS Produkte GmbH, Am Heisterbusch 1, 19258 Gallin, Deutschland (Germany)

Z 02502 M DS V2 0618

Summary of Contents for TS-20143

Page 1: ...F higkeiten oder Mangel an Erfahrung und oder Wissen d rfen das Ge r t benutzen wenn sie beaufsichtigt oder be z glich des sicheren Gebrauchs des Ger tes unterwiesen wurden und die daraus resultie re...

Page 2: ...keit LL niedrige Geschwindigkeit Das Ger t h rt automatisch auf zu heizen sobald die ein gestellte Temperatur im Raum erreicht ist K hlt der Raum wieder ab beginnt es automatisch wieder mit dem Heiz v...

Page 3: ...Gebl seunter st tzung ja nein Bei Nennw rmeleistung elmax 0 515 kW Art der W rmeleistung Raumtemperaturkontrolle bitte eine M glichkeit ausw hlen Bei Mindestw rme leistung elmin 0 450 kW einstufige W...

Page 4: ...ties or a lack of experience and or knowledge if they are supervised or have received instruction on how to use the device safely and have under stood the dangers resulting from failure to com ply wit...

Page 5: ...e device automatically stops heating as soon as the preset temperature in the room has been reached Once the room cools down again the device begins heating again automatically for as long as it is sw...

Page 6: ...mbient temperature yes no Auxiliary energy consumption fan driven heat output yes no At rated heat output elmax 0 515 kW Type of heat output room temperature control please select one option At minimu...

Page 7: ...ssances lorsqu elles sont sous surveillance ou qu elles ont t instruites quant l utilisation de l appareil en toute s cu rit et qu elles ont compris les risques en d cou lant ceci sous r serve que l a...

Page 8: ...uffer d s que la temp rature programm e est atteinte dans la pi ce Si la pi ce se rafra chit nouveau il se r enclenche auto matiquement pour produire de la chaleur aussi longtemps qu il reste allum 5...

Page 9: ...Pour une puissance thermique nominale elmax 0 515 kW Type de puissance thermique contr le de la temp rature de la pi ce merci de s lectionner une seule possibilit Pour une puissance thermique minimale...

Page 10: ...mogens of personen die niet beschikken over voldoende ervaring en of kennis mogen het apparaat gebruiken wan neer zij onder toezicht staan en instructies heb ben gekregen hoe het apparaat op een veili...

Page 11: ...ed knop 8 de snelheid van de warmteblazer instellen HH hoge snelheid LL lage snelheid Het apparaat stopt automatisch met verwarmen zodra de ingestelde temperatuur in de ruimte is bereikt Koelt de ruim...

Page 12: ...bruik warmteafgifte met ventilatoronder steuning ja nee Bij nominaal ver warmingsvermogen elmax 0 515 kW Soort verwarmingsvermogen ruimtetemperatuur regeling a u b een optie selecteren Bij minimaal ve...

Reviews: