RM-208 CB.13.01 Easy Line Documentation
RDN 10000795
16
20.03.2019
11 Technical specifications
Application
Data
Supply voltages
110 V AC 50-60 Hz
Power consumption: max. 53 VA
Back-up fuse: max. 4 A
Signal inputs
24 V DC, operate ensuring isolation
Signal output
Relay outputs, max. 2 A, 250 V
or 1 A, 30 V DC
Control outputs for valves
For valves with a rated voltage of 24 V DC,
can be expanded to 120 outputs,
Output power in pulse mode 42 Watt
Outputs for expansion
modules
Supply voltage and pulse wires to the expansion modules
Device fuse
0.3 A / M, 5 x 20 mm, 250 V
Type Bell 5MT 300 mA
(ESKA UL 521.012)
Temperature range
-20°C to +50°C
Protection class
Housing IP-66 not evaluated by UL / Type 5
Installation torque of cover screws: 1,5 Nm
Weight
approx. 0.8 kg
Installation height
max. 2000 m above M.S.L.
Electrical connections
Tension spring terminals
Permissible wire gauge
single-wire: 22 ... 16 AWG / 0.5 ... 1.5 mm²
Flexible:
22 ... 16 AWG / 0.5 ... 1.5 mm²
Cable glands
Size
Sealing range
Cord diameter
Installation
range
torque
M16x1.5
5 … 10 mm
5.6 ... 10 mm
2.0 Nm
M20x1.5
8 … 13 mm
9 ... 13 mm
2.7 Nm
M25x1.5
11 … 17 mm
13 ... 17 mm
5.0 Nm
Disclaimer
The contents of this documentation has been verified for correctness and completeness. Nevertheless, errors can not be excluded