background image

           

EasyIO FC20 User Reference v1.3

 

Software Configurations 

In order to connect to the new EasyIO FC Series via the Virtual Machine, some files are needed. 

EasyIO FC 

series is not a Sedona Controller 

but it uses the Sedona environment to program it.  

Hence there will be no extra software needed.  
These kits are hardware dependent. Only works for FC series.  
 
The FC series comes with a User Interface to configure the Temp Table as well. It works only with Sedona 
workbench or Embedded Sedona Workbench in Niagara Workbench.  
 
Follow the below instructions before connecting to the controller via Sedona Workbench.  
 

Install platform files and kits files 

 

Step 1 

Get the required files from EasyIO technical support at 

[email protected]

. The files are the Sedona kits 

and platform manifest for the EasyIO FC series.  
 

Step 2 

Close the workbench.  
Locate the Sedona folder in the Niagara installation directory;  
 

Niagara Version 

Sedona directory 

Niagara Ax 3.5.xx 

Niagara\niagara 3.5.xx\sedona\ 

Niagara Ax 3.6.xx 

Niagara\niagara 3.6.xx\sedonaBundles\sedona 
1.1.xx\sedona\ 

Niagara Ax 3.7.xx 

Niagara\niagara 3.7.xx\sedona\ 

 

Step 3 

Copy and merge the 2 folders that obtain from EasyIO technical support.  

The 2 folders are: platform and 

kits 

For Niagara Ax 3.5 User go to 

step 4. 

For Niagara Ax 3.6 User go to 

step 5. 

For Niagara Ax 3.7User go to 

step 6. 

 

 

Step 4 

For  Niagara  Ax  3.5.xx  user.  Drag  and  drop  it  in  to  the  Sedona  root  folder.  Hit  “Yes”  on  the  pop  up  to 
merge the files.  

Summary of Contents for FC 20

Page 1: ...EasyIO FC20 User Reference v1 3 EasyIO FC 20 DDC User Reference V1 3...

Page 2: ...erence v1 3 Document Change Log 1st April 2013 Document created 13th July 2013 Software configurations added 27th Sept 2014 FC now support pulse input 6th June 2015 Serial address image Serial Port se...

Page 3: ...EasyIO FC20 User Reference v1 3 Disclaimer EasyIO FC 20 is a product by EasyIO Holdings Pte Ltd Sedona Framework is a trademark of Tridium Inc...

Page 4: ...ns 6 Power supply Connection 6 RS485 Connection 7 Jumpers Setting 9 Digital Output Wiring Connection 11 Universal Input Connection 12 Analog Output Connection 13 Buttons and Indications 14 Software Co...

Page 5: ...as Roof Top Units Fan Coils AHU s package units etc EasyIO FC20 controller comes with built in bootloader program Built in bootloader program will enable user to upgrade firmware without sending back...

Page 6: ...specification for the working range In order to avoid damage on the controller input output devices and RS485 connection use individual power supply for each controller If a single power supply is use...

Page 7: ...he controller should be wired in daisy chain network topology as shown as image below If wire branch can be avoided keep it as short as possible and never connect more than one device to the wire bran...

Page 8: ...ACnet MSTP Modbus Baud Rate 19 2K Parity even Data Bit 8 Not editable Stop Bit 1 BACnet Baud Rate 19 2K Port 1 is used to perform Firmware flashing FwTool exe Virtual Device for program downloads FcVi...

Page 9: ...rotocol toggle the 1 of the dip switch to ON The remaining DIP switch 2 8 are for BACnet MSTP ID or Modbus Serial ID address 0 is not available it will be set to 1 depending on DIP switch 1 selection...

Page 10: ...tch number Functions Remarks 1 Protocol Setting On Bacnet MSTP Off Modus RTU 2 Serial Address Address 64 MSB 3 Serial Address Address 32 4 Serial Address Address 16 5 Serial Address Address 8 6 Serial...

Page 11: ...ing Connection EasyIO FC 20 has four general purpose isolated digital output connections relay output Each relay output able to drive up to 1A 30VDC 48VAC load It does not output voltage or current It...

Page 12: ...s 8 customizable temperature lookup tables for resistance to temperature translation The commonly used Thermistor like 10K 10K with Shunt 1K Balco and 1K Platinum are all supported b Voltage Two selec...

Page 13: ...Output can be configured to drive voltage or current output via hardware jumper setting and internal register settings The working range for voltage is 0 10V and for current either 0 20mA or 4 20mA F...

Page 14: ...ED to indicate its current state Button and LED indications LED Conditions Description 1 PWR PWR is used to indicate the presence of 24VAC power source and internal power 2 ERR ERR is to indicate when...

Page 15: ...les and kits files Step 1 Get the required files from EasyIO technical support at support easyio com The files are the Sedona kits and platform manifest for the EasyIO FC series Step 2 Close the workb...

Page 16: ...EasyIO FC20 User Reference v1 3 Step 5 For Niagara Ax 3 6 xx user Drag and drop it in to the sedona root folder Hit Yes on the pop up to merge the files...

Page 17: ...6 For Niagara Ax 3 7 xx user Drag and drop it in to the sedona root folder Hit Yes on the pop up to merge the files Step 7 Re open workbench and connect to EasyIO FC 20 controller Refer to EasyIO FC 2...

Page 18: ...EasyIO FC20 User Reference v1 3 Technical Support For technical issue please contact Email support easyio com...

Reviews: