EF4100 Overall Dimensions

  

Figure 2

Provide adequate clearances around air openings into the

com bustion cham ber and adequate accessibility clearance for
servicing and proper operation. Never obstruct the front
opening of the heater.

The heater m ay be installed as a free-standing unit m ount-

ed on a noncom bustible protective floor pad or hearth, or it
m ay be m ounted into an existing U. L. approved wood stove
chim ney using a Hearth Extension (p/n 11099).  Non-com bu-
stible floor protection is required and m ust be used when
placing the heater on any com bustible m aterial.

The pellet heater m ust be operated with a power source

and will not operate using natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, the heater will autom atically switch to 12 volt
power. An 

optional

 backup battery is available for the  unit

which lasts approxim ately 48 hrs on high and 72 hrs on low.
A bigger battery m ay be purchased if desired for longer
durations.

The EasyFire Pellet Heater has been listed by OMNI-Test

Laboratories, Inc. to ASTM, U.L.,and EPA Standards.

CAUTION:

 Do not connect this unit to a chim ney flue serving

another appliance.

Use only listed Type "L" pellet vent or stainless liner and

com ponents for installation. Failure to use listed com ponents
will void your warranty.  See pipe m anufacturer instructions for
installation instructions.

OUTSIDE COM BUSTION AIR IS M ANDATORY IN
M OBILE OR M ODULAR HO M E INSTALLATIONS.

 SEE

SECTION ON OUTSIDE AIR INSTALLATION.

C AU T IO N : D O  N O T  C O N N E C T  T O  A N Y  AIR
DISTRIBUTION DUCT OR SYSTEM .

INSTALLATION INSTRUCTIONS

Check with local building officials for specific code
requirem ents.

A listed, type "L" Pellet Vent Pipe or Stainless Liner is
MANDATORY on all installations.

W ARNING:

 

Installation  of  a  M obile  Attachm ent  Hom e

Kit P/N 10412 and outside com bustion air is mandatory
in mobile or modular hom e installations

 although it m ay

also be used in all residential applications. 

An outside air inlet M UST be provided for

com bustion and ventilation air.

  The air inlet m ust

rem ain unrestricted while unit is in use.  Outside air
connection is located in the rear of the heater (

Figure 1

).

NOTE:

 Vent Pipes’ inner diameters may vary.

For Vent Pipes Ø3.00" or smaller, use SPI Exhaust Vent
Adapter p/n 11076.

This adapter is used on Selkirk Metalbestos™  and other
Ø2.950" I.D. Pellet Vent Pipes.

Use conduit pipe or m etal flex pipe and/or fittings to m ake
the air intake hook-up.

Also, the 

structural integrity of the mobile hom e floor,

w alls and ceiling/roof must be m aintained

.

1.

Clean and inspect the fireplace and its chim ney for any
structural defect that m ay cause any future problem s.
Secure gas piping that is installed with a cap and verify
there are no leaks. Seal ash dum p or any other access to
the firebox area. Fix the dam per in an open position or
rem ove it as required for vent pipe installation.

2.

Verify the required hearth and side and clearances to
m antels 

(fig. 2 & 3)

.

Summary of Contents for EF4001B AutoLite

Page 1: ...n More frequent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartments burn pot and circulat ing air passageways of...

Page 2: ...lation instructions OUTSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM IN...

Page 3: ...earth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation aro...

Page 4: ...erature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet...

Page 5: ...passage through a wall or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or...

Page 6: ...e your cleaning and maintenance time Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand Thi...

Page 7: ...CAUTION Moving parts may cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE...

Page 8: ...sually means that the air flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may...

Page 9: ...opper lid must be closed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open th...

Page 10: ...croprocessor is automatically adjusting the feed and air based on temperature This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwell...

Page 11: ...th a soft cloth and non abrasive cleaner 6 Cleaning Polishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use W index or comparabl...

Page 12: ...ssive ash and clogging particularly the vent cap Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow This automatic shut down in case of flue clogging is a...

Page 13: ...RD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL...

Reviews: