2
EF4100 Overall Dimensions
Figure 2
Provide adequate clearances around air openings into the
com bustion cham ber and adequate accessibility clearance for
servicing and proper operation. Never obstruct the front
opening of the heater.
The heater m ay be installed as a free-standing unit m ount-
ed on a noncom bustible protective floor pad or hearth, or it
m ay be m ounted into an existing U. L. approved wood stove
chim ney using a Hearth Extension (p/n 11099). Non-com bu-
stible floor protection is required and m ust be used when
placing the heater on any com bustible m aterial.
The pellet heater m ust be operated with a power source
and will not operate using natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, the heater will autom atically switch to 12 volt
power. An
optional
backup battery is available for the unit
which lasts approxim ately 48 hrs on high and 72 hrs on low.
A bigger battery m ay be purchased if desired for longer
durations.
The EasyFire Pellet Heater has been listed by OMNI-Test
Laboratories, Inc. to ASTM, U.L.,and EPA Standards.
CAUTION:
Do not connect this unit to a chim ney flue serving
another appliance.
Use only listed Type "L" pellet vent or stainless liner and
com ponents for installation. Failure to use listed com ponents
will void your warranty. See pipe m anufacturer instructions for
installation instructions.
OUTSIDE COM BUSTION AIR IS M ANDATORY IN
M OBILE OR M ODULAR HO M E INSTALLATIONS.
SEE
SECTION ON OUTSIDE AIR INSTALLATION.
C AU T IO N : D O N O T C O N N E C T T O A N Y AIR
DISTRIBUTION DUCT OR SYSTEM .
INSTALLATION INSTRUCTIONS
Check with local building officials for specific code
requirem ents.
A listed, type "L" Pellet Vent Pipe or Stainless Liner is
MANDATORY on all installations.
W ARNING:
Installation of a M obile Attachm ent Hom e
Kit P/N 10412 and outside com bustion air is mandatory
in mobile or modular hom e installations
although it m ay
also be used in all residential applications.
An outside air inlet M UST be provided for
com bustion and ventilation air.
The air inlet m ust
rem ain unrestricted while unit is in use. Outside air
connection is located in the rear of the heater (
Figure 1
).
NOTE:
Vent Pipes’ inner diameters may vary.
For Vent Pipes Ø3.00" or smaller, use SPI Exhaust Vent
Adapter p/n 11076.
This adapter is used on Selkirk Metalbestos™ and other
Ø2.950" I.D. Pellet Vent Pipes.
Use conduit pipe or m etal flex pipe and/or fittings to m ake
the air intake hook-up.
Also, the
structural integrity of the mobile hom e floor,
w alls and ceiling/roof must be m aintained
.
1.
Clean and inspect the fireplace and its chim ney for any
structural defect that m ay cause any future problem s.
Secure gas piping that is installed with a cap and verify
there are no leaks. Seal ash dum p or any other access to
the firebox area. Fix the dam per in an open position or
rem ove it as required for vent pipe installation.
2.
Verify the required hearth and side and clearances to
m antels
(fig. 2 & 3)
.