Step 6

 - Open the door till fully ajar, press 

Enter button

.  The open position LEDS will then flash 

green. 
 

Step 7

 - Release door. 

 

Step 8

 - With door in the closed position, press 

Enter button

.  A second non-labelled LED will flash 

green then stop. 
 

Step 9

 - Stand clear from the door.  The door will then quickly open halfway and then close. 

 

Step 10

 - Press and hold 

Enter button

 until DS9 LED flashes to confirm you have exited the 

programming. 

 
 

Variable Open and Close Options 
 

To enter programming mode: 
 

Step 1

 - Press and hold 

Enter

 and 

Select buttons

 for 3 seconds. 4 green LEDS will flash. 

 

Step 2

 - Wait for the 4 green LEDS to stop flashing, and 1 CLS green LED to light. 

 

Step 3

 - Press and release 

Select button

.  The green CLS LED will go off, and the green OP LED 

position light will come on.  
 

Step 4

 - Press 

Select button

 until desired operating mode is highlighted by green LED 

 

Step 5

 - Press 

Enter button

 once. 

 

Step 6

 - Press 

Enter

 

button

 again and hold for 3 seconds. 

 
You will now have exited the programming.  

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PUSH

Page 1: ...ical skill capability and familiarity in the field of operators and closing devices for swing doors Any person who feels that they cannot satisfy those requisites should not attempt installation of th...

Page 2: ...applications that occasionally requires powered operation A regenerative drive system charges an onboard battery pack eliminating the need for electrical power Easydor should be applied to doors usin...

Page 3: ...that they cannot satisfy those requisites should not attempt installation of the Easydor If an Easydor is installed incorrectly and subsequently the services of a Fireco engineer are required a call o...

Page 4: ...s 2 Black socket head bolts Bag 2 6 Philips Head screws 6 silver washers 2 steel mounting pins 2 large socket head bolts 2 small socket head bolts Bag 3 4 wall mount screws 2 small socket head bolts 9...

Page 5: ...Easydor fitting instructions PUSH door Step 1 Line up template to top of door...

Page 6: ...op Width cannot exceed 20mm otherwise the body of the Easydor will foul with it when in the closed position Step 3 Align Template to the edge of the door Step 4 Using a centre punch mark the mounting...

Page 7: ...ounting triangle Step 7 Using a centre punch mark the door arm pivot bracket hole locations Step 8 Using a 4 mm drill bit drill the door arm pivot bracket holes Step 9 Secure the door arm pivot bracke...

Page 8: ...drilled holes in the door and fix using 6 x Phillips head screws and washers from Bag 2 but do not tighten Step 12 If using operating bracket Template D leave a 12 7mm space between the operating brac...

Page 9: ...ns from Bag 2 into the lower threaded holes in the mounting bracket using an adjustable spanner If the operator is being mounted to Template E tighten the operator mounting pins into the upper threade...

Page 10: ...or arm coupling screws facing up and the door arm touching the face of the door position the larger end of the door arm onto the operator output shaft Step 19 Tighten the door arm coupling screws even...

Page 11: ...locking screws of the adjustable arm bracket Step 22 Remove the domed socket head bolt from the operating arm bracket insert the Easydor arm to the operating arm bracket and reaffix the domed socket h...

Page 12: ...Step 23 Insert Allen key into hole above battery slot Adjust clockwise to increase spring tension to ensure door closes in a controlled manner...

Page 13: ...ivation Pad Step 6 Using a drill but appropriate to the wall screw drill into the wall Insert rawl plugs if necessary Step 7 Using 2 wall mount screws from Bag 3 use Philips Head screwdriver to fix Do...

Page 14: ...oor Step 1 Using 9 64 Allen Key remove Base Plate Cover if it is attached Step 2 Connect battery pack to the Easydor Body using the 3 pin connector socket ensuring the wires do not interfere with the...

Page 15: ...ns together for 3 seconds Step 4 4 LEDS will flash green repeatedly for a few seconds A red closed position LED will then remain lit Step 5 With the door in the closed position press the Enter button...

Page 16: ...irm you have exited the programming Variable Open and Close Options To enter programming mode Step 1 Press and hold Enter and Select buttons for 3 seconds 4 green LEDS will flash Step 2 Wait for the 4...

Page 17: ...kwise to decrease speed of door operation The LEDS will light to indicate strength Press Enter button once Press Enter button again and hold for 3 seconds You will now have exited the programming Hold...