11.4 How to set the slave monitor address

11.5 How to set the  monitor panel on 







cei



 



Unlock mode:

Unlock time:

The unlock time can be changed at any time. It can be set from 1 to 9 seconds.Code 
numbers from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds.

There are two unlock modes: 1. Power-on- to-unlock type: unlock mode=0(by default)     
                                             2. Power-off-to-unlock type: unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1

Maximum of 4 monitors can be connected in one apartment, one master monitor together 
with  3 slave monitors, addresses must be the same.(note: must have one monitor to be 
set as master monitor)
Code  8000 is used to set the master monitor.
Code  8001 is used to set the  first slave monitor .
Code  8002 is used to set the  second slave monitor .
Code  8003 is used to set the  third slave monitor .

In default mode, when receive a call, the master and slave monitors will ring at the same 
time, only the master monitor will display the image while the slave monitors do not.  The 
settings can be changed, the system can be set to allow the master monitor and all the 
slave monitors to display video at the same time when receiving a call, input the code 
number of 8006  on each slave monitor.

11.6 How to set the unlock parameter

Summary of Contents for CDV43

Page 1: ...2 Wire Video Intercom System CDV43 USER MANUAL EN Read this manual carefully before using the product keep in a safe place for future use ...

Page 2: ... GND NC 3 ON L1 L2 DIP 4 5 6 1 2 SW SW RING GND NC 3 ON L1 L2 DIP 4 5 6 SW SW Door bell call button connection port Ring GND Extra buzzer connection port NC Reserved L1 L2 2 wire Bus terminal DIP switches Total 6 bits can be configured Bit1 Bit5 Used to set User Code Bit6 Set to ON when the monitor is at the end of the line EOL or operates with a DBC4A otherwise set to OFF 2 Monitor Mounting 1 Par...

Page 3: ...ess CALL button on the outdoor station the Monitor rings and the screen will display the visitors image Press Menu Close button in standby mode the main menu page will be shown as follows 1 Use the screws provided to fix the Mounting Bracket fits a standard UK single gang flush back box if required Fitting accessories includes a Bracket Two x M4 x 25mm screws are needed for fastening the Mounting ...

Page 4: ...ll conversation is started and the other monitors will stop ringing 3 Call Guard Unit A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started When the monitor is in standby mode press Menu button to enter main menu page Use button to move up down to select Intercom Call press Menu button to enter the Select Intercom...

Page 5: ...to confirm 6 Divert Call Function Requires CDV GSM 7 Do Not Disturb Function When the monitor is in standby mode press Menu Button to enter main menu page Use button to move up down to select Don t Disturb press Menu button or press Mute button indicator directly to enter the No Disturb page there are 4 options 1 No Divert calls from outdoor station will not be diverted 2 If No Answer Calls from o...

Page 6: ...is in standby mode press Menu Button to enter main menu page Use Button to move upward downward to select Light option press Menu Button to enter the Light Option page there are 3 options 1 Turn On Select it to open the staircase light the light will be turned off automatically after 60 seconds 2 Turn On 5min Select it to open the staircase light the light will be turned off automatically after 5m...

Page 7: ...nu button to confirm Press Unlock button and hold for 3secs Use button to increase decrease the value required and press Menu button to confirm 11 1 How to enter the installation setting page A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started The code number of 8004 is used to set the monitor as a guard unit mo...

Page 8: ...artment one master monitor together with 3 slave monitors addresses must be the same note must have one monitor to be set as master monitor Code 8000 is used to set the master monitor Code 8001 is used to set the first slave monitor Code 8002 is used to set the second slave monitor Code 8003 is used to set the third slave monitor In default mode when receive a call the master and slave monitors wi...

Page 9: ...termination switch EOL this has to be set to ON if the Monitor is at the end of the line bus otherwise set to OFF 11 8 User Code Setup Flashes slowly enabled 11 7 How to enable disable auto unlocking Disabled by default Function Description Auto unlocking allows the door to unlock after 5 seconds of a placed call from the door station without the need to answer or unlock the door this allows the u...

Page 10: ... 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 ...

Page 11: ...all press Menu button the Adjustment menu will be displayed Use the Menu to select the option required use button to increase decrease the value press the Return button to quit the adjust page 1 A total of 4 screen modes can be selected in 3 The Volume options are for ring tone and talking volume adjustment door station BUS IM BUS DS PC6 AC Doorbell Button 1 2 NC GND RING sw sw 3 ON L1 L2 DIP 4 5 ...

Page 12: ...D4 V1 14 Specifications Power supply for indoor monitor DC 20 28V Power consumption Standby 0 17W Working status 4 7W Monitor screen 4 3 inch digital color TFT Display Resolutions 480 R G B x 272 pixels Video signal 1Vp p 75Ω CCIR standard Wiring 2 wires non polarity Monitor time 40 seconds Talking time 90 seconds Dimensions 137 H 137 W 17 D mm ...

Reviews: