7

DRAINING FLUID

•  Remove the Inlet Adapter from the Inlet/Spout at the top of the Evacuator by pushing in firmly 

and turning 15° Clockwise to unlock the latch.

•  Grasp Knob and pull out to remove.

 

•  Before proceeding to empty the Fluid 

Canister, note the “Fluid Drain Limited 
Line” molded into both sides of the Fluid 
Canister 

(FIG 7)

. Allowing the fluid level 

in the Canister to go above this line while 
tilting the Canister to empty its contents 
may allow fluid to escape through the 
built-in Safety Valve.

•  Tilt Evacuator Canister to allow accumu-

lated fluid to pour out of Spout.

MAINTENANCE

• 

DO NOT

 allow fluid to remain in Evacuator Canister.

•  DO NOT use Evacuator Canister as a fluid storage vessel.
•  Remove Nylon Tube or Silicone Hose when done, allow to drain fully then clean out by flushing 

with a suitable solvent.

•  If a clog in a Nylon Tube should occur, use the Tube Clog Clearing Wire by inserting into the end 

of the tube and pushing until the material causing the clog is discharged.

EXPOSURE TO AUTOMOTIVE FLUIDS CAN BE A HEALTH HAZARD! 

  • Contents can splash into eyes. Be sure to follow all precautions listed  

  on fluid containers before using.

  • Wear ANSI Z87.1 approved eye protection while using extractor.
  • Wear appropriate chemical resistant gloves while handling fluids.

 

  Used automotive fluids are hazardous materials and should be disposed of  

in compliance with local regulations.

 

  To avoid leakage from the built-in Safety Valve when draining fluid, DO NOT 

allow fluid level in the Canister to exceed the “Fluid Drain Limited Line”.

FIG. 7

Summary of Contents for Fairmount Tools 31805

Page 1: ...6 5L MANUAL FLUID EVACUATOR INSTRUCTIONS Item 31805...

Page 2: ...10mm to 0 27 7mm Tube Connector 1 0 38 10mm to 0 23 6mm Tube Connector 1 Inlet Adaptor with 59 1 5m Silicone Hose with Shut off Clip and Brake Bleeder Attachment DANGER indicates a hazardous situation...

Page 3: ...Drain flammable liquids immediately after extraction Flammable liquids emit explosive vapors Keep away from sources of sparks flames or excessive heat INJURY HAZARD DO NOT use for extraction of danger...

Page 4: ...irmly until seated then turn 15 Counter Clockwise to lock into position FIG 1 FOR FLUID EXTRACTION Determine which Nylon Tube best fits into the dipstick tube or other orifice being accessed Using the...

Page 5: ...he oil pan or other vessel Unfold the Wire Pedal from the base of the Evacuator FIG 4 Place a foot on the Wire Pedal for stabilization Raise the Pump Handle to the top of it s stroke then push downwar...

Page 6: ...this point Before opening bleeder screw Raise the Pump Handle to the top of it s stroke then push downward to the bottom of the stroke for complete pumping action NOTE Each full stroke is approx 15 3...

Page 7: ...OT use Evacuator Canister as a fluid storage vessel Remove Nylon Tube or Silicone Hose when done allow to drain fully then clean out by flushing with a suitable solvent If a clog in a Nylon Tube shoul...

Page 8: ...eastwood com PDF version of this manual is available online eastwood com 31805manual The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 343 9353 Outside US 610 718 8335 F...

Reviews: