FOR BRAKE OR CLUTCH BLEEDING

FIG. 5

 

IMPROPER MOTOR VEHICLE BRAKE WORK OR OTHER MECHANICAL WORK  
CAN RESULT IN INJURY OR DEATH!

  Performing brake work without adequate training in motor vehicle brake 

systems can cause injury, death and vehicle accidents. DO NOT attempt to 
use this tool or begin motor vehicle brake work without proper training and  
a thorough understanding of motor vehicle braking systems.

FIG. 6

•  DO NOT open bleeder screw at this point!
•  Before opening bleeder screw: Raise 

the Pump Handle to the top of it’s stroke 
then push downward to the bottom of 
the stroke for complete pumping action. 

NOTE:

 Each full stroke is approx.  

15” (380mm).

•  Repeat pumping action until a significant 

vacuum has been built up. 

NOTE:

 6 to 12 

pumps may be required to achieve suf-
ficient vacuum.

•  The bleeder screw may be opened 

slightly allowing brake fluid and air to be 
drawn out. 

NOTE:

 To stop flow of fluid 

at any time, close the Shut-off Clip by 
pressing inward on the flexible tab until 
it crimps the tube and latches 

(FIG 5)

To open, release latch. 

NOTE:

 To relieve 

any excess vacuum, press the Pressure 
Release Button at the top edge of the 
Evacuator lid 

(FIG 6)

.

Summary of Contents for Fairmount Tools 31805

Page 1: ...6 5L MANUAL FLUID EVACUATOR INSTRUCTIONS Item 31805...

Page 2: ...10mm to 0 27 7mm Tube Connector 1 0 38 10mm to 0 23 6mm Tube Connector 1 Inlet Adaptor with 59 1 5m Silicone Hose with Shut off Clip and Brake Bleeder Attachment DANGER indicates a hazardous situation...

Page 3: ...Drain flammable liquids immediately after extraction Flammable liquids emit explosive vapors Keep away from sources of sparks flames or excessive heat INJURY HAZARD DO NOT use for extraction of danger...

Page 4: ...irmly until seated then turn 15 Counter Clockwise to lock into position FIG 1 FOR FLUID EXTRACTION Determine which Nylon Tube best fits into the dipstick tube or other orifice being accessed Using the...

Page 5: ...he oil pan or other vessel Unfold the Wire Pedal from the base of the Evacuator FIG 4 Place a foot on the Wire Pedal for stabilization Raise the Pump Handle to the top of it s stroke then push downwar...

Page 6: ...this point Before opening bleeder screw Raise the Pump Handle to the top of it s stroke then push downward to the bottom of the stroke for complete pumping action NOTE Each full stroke is approx 15 3...

Page 7: ...OT use Evacuator Canister as a fluid storage vessel Remove Nylon Tube or Silicone Hose when done allow to drain fully then clean out by flushing with a suitable solvent If a clog in a Nylon Tube shoul...

Page 8: ...eastwood com PDF version of this manual is available online eastwood com 31805manual The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 343 9353 Outside US 610 718 8335 F...

Reviews: