MAINTENANCE

•  Add several drops of air tool oil before each use by dropping directly into the air inlet.
•  If tool is to be unused for an extended period, add 10 drops of air tool oil directly to the air inlet, 

rotate the tool motor by hand several times to distribute the oil throughout the motor then store 
the tool, handle up.

PROBLEM

CAUSE

CORRECTION

Tool doesn’t 

respond to 

Paddle  

depression

Insufficient vol-

ume of air (CFM) 

to operate tool.

Verify sufficient air supply to tool.  

(3.1 CFM @ 90 PSI minimum requirement)

Moisture or other 

contamination in 

air supply

Check for moisture in air line and tool air inlet.

Tool perfor-

mance is slow 

or sluggish

Insufficient vol-

ume of air (CFM) 

to operate tool

Verify sufficient air supply to tool.  

(3.1 CFM @ 90 PSI minimum requirement).

Moisture or other 

contamination in 

air supply

Check for moisture in air line and tool air inlet.

Air Motor is lack-

ing lubrication

Stop use immediately and add air tool oil  

directly to air inlet.

Tool is exces-

sively noisy/

emits high 

pitched sound

Air Motor is lack-

ing lubrication

Stop use immediately and add air tool oil  

directly to air inlet.