MAINTENANCE
• Unplug unit and inspect the pump intake grill
after every hour of cleaning
(Fig D)
.
Clean more often if removing excessively heavy
deposits of grease and grit. Important Note:
Failure to clean pump intake will result in
diminished fl uid fl ow, cleaning effectiveness
and eventual pump motor failure.
• If it becomes apparent that the pump intake
grill requires cleaning more often, it is likely that
the cleaning solution needs to be replaced and an accumulation of sediment from the Tub bottom
needs to be removed.
- Drain and pour drain cleaning solution into suitable containers and dispose of properly.
TROUBLESHOOTING
• If Fluid stops fl owing or fl ows sporadically, the Pump may not be fully submersed. The Pump
must be fully under the fl uid surface level to work properly (
Fig C
).
• If pump intake cleaning does not restore pump performance, an accumulation of dirt and grit
may be present in the Flexible Metal “Gooseneck” Fluid Outlet Tube.
- Unplug unit and remove Flexible Metal “Gooseneck” Fluid Outlet Tube and check for
obstructions lodged in tube and remove.