ASSEMBLY

•  Thread the Flexible Metal “Gooseneck” Fluid 

Outlet Tube onto the Pump Outlet Fitting 

(Fig A)

.

•  Place the Parts Cleaning Tray over the ledges 

on the walls of the tub. Make sure the Nozzle 
of the Flexible Metal “Gooseneck” Fluid Outlet 
Tube is shaped to be facing in and downward 
toward the center of the Tub 

(Fig B)

.

•  Fill unit with suitable, water-based degreasing 

solution suffi ciently to cover the entire Pump 
(approx. 1.5 gallons) 

(Fig C)

.

 

Important Notes:

 

 

 

-  Follow degreasing solution mixing, usage    

 

  and safety label instructions carefully 

  

before 

using.

 

 

-  Be sure the cleaning solution level fully    

 

  covers the Pump or it will not function    

  

properly. 

•  Plug power cord into an approved, grounded 

and GFI equipped 120 Volt AC, 60hz. outlet.

•  Turn Power Switch to the “On” position. 

The Parts Washer is now ready for use.

OPERATION

•  Place parts to be cleaned on the Parts Tray.
•  Allow cleaning solution to fl ow completely over 

the part surface, wetting it completely. Allow 
time for solution to soften any grease and 
debris then use a suitable parts cleaning 
brush to remove stubborn deposits.

•  Let excess solution drain from parts then 

remove from washer and rinse in warm water.

•  When done, turn pump to the off position, 

close lid and unplug unit.

Your 

Eastwood 3.5 Gallon Benchtop Parts Washer

 is specifi cally designed with heavy-duty 

components and a quality powder-coated fi nish to provide years of trouble-free service. It features 
a fl exible, positionable metal “Gooseneck” fl uid outlet tube with nozzle for added convenience.

SAFETY INFORMATION

SPECIFICATIONS

•  120 Volt AC, 60hz current requirement 
•  Maximum pump capacity @ outlet: 1 gallon per minute
•  3.5 gallon tub capacity, 1.5 gallon operating capacity

INCLUDES

(1)  3.5 Gallon capacity tub (1.5 gallon actual operating capacity)
(1) Parts tray
(1)  Flexible, positionable metal “Gooseneck” fl uid outlet tube with nozzle

READ INSTRUCTIONS! 

 

Thoroughly read and understand manual before using this Parts Washer Tool. 
Save for future reference.

WARNINGS! 

• 

NEVER

 use solvent based or fl ammable cleaning agents in this parts washer. 

The recirculating pump is designed to operate with water based cleaning agents 
only. Solvents will quickly destroy the pump and could present a fi re hazard.

• 

DO NOT

 use paint or powder dissolving solutions that would remove the 

powdercoated fi nish of the Tub and components.

• 

NEVER

 let parts washer run while unattended. Clogging of the fi lter and resulting 

overheating of the pump motor can occur.

• 

ALWAYS

 plug into an approved, grounded and GFI equipped 120 Volt AC, 

60hz. outlet.

•  For indoor use only.
• 

ALWAYS

 wear chemical resistant gloves and adequate eye protection.