background image

6

 

Eastwood Technical Assistance: 800.544.5118  >>  [email protected]

TORQUE WRENCH USE AND CARE

•  Do not exceed the permitted maximum torque value for this tool. Over torquing the unit can 

cause permanent damage.

•  Be sure all accessories including adaptors, extensions and sockets are rated to match or 

exceed the torque being applied.

•  Use the correct size socket for the fastener.
•  Do not use sockets that are cracked or damaged.
•  Do not use the Torque Wrench near corrosive gas or liquid.
•  Keep away from strong magnetic fi elds.
•  Never hold or operate the unit with wet or greasy hands.
•  Never apply torque when the tool is turned off or permanent damage can occur.
•  Check that the Torque Wrench capacity matches or exceeds each application 

before proceeding.

•  Do not drop and avoid excessive bumps or shock to this tool.
•  If the tool is to be unused for an extended period of time, remove the batteries to prevent

damage from leakage.

To order parts and supplies: 800.345.1178  >>  eastwood.com 

7

Summary of Contents for 13630

Page 1: ...ORQUE WRENCH INSTRUCTIONS Part 13630 IMPORTANT Please read these instructions thoroughly and carefully before operation The instructions will provide you with important information regarding operation warnings and safety precautions ...

Page 2: ...alue Change the rotation of Angle in a CW or CCW direction Enter Program Settings Mode D Button to zero out the torque and angle values E Button for display illumination for selecting the next decimal place enter Angle measurement mode A B D E C PREPARATION FOR USE Open the cover of the battery compartment by turning it counter clockwise Insert four AAA batteries as shown below Close the battery c...

Page 3: ... 075 0 in the display 5 When the required torque level is set press to save the value Ft lb SET To order parts and supplies 800 345 1178 eastwood com 5 NOTE If there is no button activity for 5 seconds the wrench will retain the last selection of torque and automatically switch back to Measurement Mode NOTE Erro for ERROR will show on the display when the pre set torque value exceeds 100 of the ma...

Page 4: ...sockets that are cracked or damaged Do not use the Torque Wrench near corrosive gas or liquid Keep away from strong magnetic fields Never hold or operate the unit with wet or greasy hands Never apply torque when the tool is turned off or permanent damage can occur Check that the Torque Wrench capacity matches or exceeds each application before proceeding Do not drop and avoid excessive bumps or sh...

Page 5: ...t please contact The Eastwood Technical Assistance Service Department 800 544 5118 email techelp eastwood com PDF version of this manual is available online eastwood com 13630manual The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 345 1178 outside US 610 718 8335 Fax 610 323 6268 eastwood com ...

Reviews: