background image

4

 

Eastwood Technical Assistance: 800.544.5118  >>  [email protected]

To order parts and supplies: 800.345.1178  >>  eastwood.com 

5

UNIT SELECTION

1.

  Once the Peak / Track mode has been set, the wrench switches to the setting of 

“UNIT SELECTION”.

 

2.

              is shown on screen, select the units between lb/ft, lb/in, kg.m, N.m by 

pressing            button.

3.

  Press          button to confi rm the unit selection. The wrench will switch to Auto Power Off 

Settings when the button is pressed.

NOTE:

 If there is no button activity for 3 seconds, the wrench will retain the last selection of Units, 

and return to measurement mode.

AUTO POWER-OFF SETTINGS

The torque wrench will be turned off automatically without any button activity over a selectable 
period. Changing the auto –off setting as follows:

1.

  Once the unit is selected, the default 

Auto-Off

 time: 

5 (5 minutes)

 will be shown on screen. 

2.

  Wait for 2 seconds without touching any buttons, or press           button to retain the default 

setting. 

3.

  Changing the wrench 

Auto-off

 time by pressing           button. Select the shut-off time 

between 

5

 minutes, 

15

 minutes or 

“OFF”

 to turn off the Auto-off function.  

4.  

Press          button to confi rm the selection. The wrench returns to measurement mode when 
the button is pressed.

NOTE:

 If there is no button activity for 3 seconds, the wrench will retain the last selection of Auto 

Power Off, and return to measurement mode.

PROGRAMMING THE TORQUE AND ANGLE

The wrench has 

5 sets

 of memory storage for pre-setting the target Torque and Angle. 

TARGET TORQUE SETTING

1.

  Press           button to turn the wrench on.

2.

  Press           button to select the memory storage number between 

M1~M5

.

3.

  Once the memory number is chosen, access the target Torque/ Angle programming 

by pressing and holding           button for 5~10 seconds.

4.

  Release           button when              is shown on screen, and the last saved torque is dis-

played. The fi rst digit of this value (“0000” ) is fl ashing. Press           button to zero the last 
saved value. Or by repeatedly pressing           button, the value of the fl ashing digit is gradually 
increased. When the desired value is reached, press           button to skip to the next decimal 
place. Repeat this process for all numeric places. (ones, tens, hundreds etc.) Example: A cor-
rect setting for 

75 lb/ft

 will read 

075.0

 in the display.

5.

  When the required torque level is set, press          to save the value.

Ft/lb

SET

TARGET ANGLE SETTING

1.

  The display skips to Angle setting automatically once the target torque is set, and displays the 

last saved angle value. The fi rst digit of this value (“0000”) is fl ashing.

2.

  Press the           button to zero the last saved value. Or by repeatedly pressing           button, 

the value of the fl ashing angle digit is gradually increased. When the desired value for this digit 
was achieved, press           button to skip to the next digit. Repeat this process for all numeric 
places in the angle value.

3.

  When the required angle is set, press           to save the value. 

NOTE:

 If there is no button activity for 5 seconds, the wrench will retain the last selection of 

Angle Setting and automatically switch to Measurement Mode.

TURNING THE DISPLAY ILLUMINATION ON / OFF

1.

  The display illumination can be turned on prior to or after programming the torque.

2.

  In order to do this, press and release the           button.

OPERATING THE TORQUE WRENCH

1.

  Select the socket required for your work.

2.

  Attach the socket fi rmly to the square drive of the torque wrench, it will be held in place by the 

ball stop of the square drive.

3.

  If possible, do not use any extensions because they may distort the torque applied to a bolt.

APPLYING PROGRAMMED TORQUE

1.

  Program the value necessary following the instructions in the 

Target Torque Setting

 section. 

2.

  Place the torque wrench on the fastener. Grip the torque wrench and PULL on the wrench with 

a slow, easy movement. Avoid jerky movements.

3.

  With the target torque pre-set, the target value is indicated on the screen.

4.

  The LED will show 

GREEN

 when you are under 50% of the programmed torque value.

5.

  When approaching the target torque value,, the LED turns to 

YELLOW

.

6.

  When you approach the programmed torque value, the buzzer will sound.

7.

  When you are 

within 2%

 of the programmed torque value, the 

RED

 LED will illuminate. 

Once the torque is reached, the buzzer will emit quicker sound sequence.

8.

 If 

you 

exceed the programmed torque by 2%

, the buzzer will emit a continuous tone and the 

LED will turn 

GREEN

.

ATTENTION: When you hear the continuous tone and the RED LED illuminates, stop pulling 
immediately or target torque will be exceeded.

NOTE:

 If there is no button activity for 5 seconds, the wrench will retain the last selection of torque 

and automatically switch back to Angle Programming.

NOTE:

 “Erro” (for ERROR will show on the display when the pre-set torque value exceeds 100% of the 

maximum torque value. After 1 second, the display returns to torque Measurement Mode.

NOTE:

 After pressing the “+” button to access the torque setting mode, without any activity after 

6 seconds, the display will return to Measurement Mode.

Reviews: