EASTRON SDM530Y User Manual
06-2018 V1.0
13
2018 EASTRON All Rights Reserved.
10-1
Long press
into the backlit
time setting interface, the current
character flashing.
Then, press
select the new
backlight lighting time.
Finally, long press
confirm
Settings.
11
User Password
Default :1000
Optional : 0 ~ 9999
11-1
Long press
to enter the user
password setting interface, the
current character flashing.
Then, press
select a new user
password.
Finally, long press
confirm
Settings.
Chapter Four. Communication Introduction
4.1
Input Register, Function Code (Hex) : 04
Register
Serial
Number
Enter Register Parameters
Register start address
Hex
Parameter Definition
Data length
(bytes)
Data
Format
Unit
High
Byte
Low Byte
30343
Total Active Power
4
Float
kWh
01
56
33841
Accumulated Used Electricity
4
Float
kWh
0F
00
33851
Balance of the meter
4
Float
$
0F
0A
33853
The sum of the accumulated recharge of
the meter
4
Float
$
0F
0C
33855
Last time recharge amount of the
meter
4
Float
$
0F
0E
33857
Accumulated Used Amount
4
Float
$
0F
10
4.2
Keep Register, Function Code (Hex) : 03 /10