background image

Publication No. 1C7070

May 1994

Supersedes 2B6835

July 1993

635883

April 1988

SITE SPECIFICATIONS

for the

Kodak RP X-Omat Processor, Model M6B

H048_0086DA

 

Eastman Kodak Company, 1994

Summary of Contents for Kodak RP X-Omat Processor M6B

Page 1: ...Publication No 1C7070 May 1994 Supersedes 2B6835 July 1993 635883 April 1988 SITE SPECIFICATIONS for the Kodak RP X Omat Processor Model M6B H048_0086DA Eastman Kodak Company 1994 ...

Page 2: ...dak s negligence or other fault To avoid hazardous conditions keep floors and floor coverings around your Kodak X Omat Processor and associated drains clean and dry at all times Any accumulation of fluids from mixing tanks drain lines etc should be cleaned up immediately In the event of an accumulation of the liquid due to backup overflow or other malfunction of the drain associated with your Koda...

Page 3: ...ons and Weights 6 Electrical Requirements 7 Basic Requirements 7 Standard Service Options 7 Water and Drain Requirements 8 Water Supply 8 Drain 8 Environmental Requirements 9 Room Ambient Temperature 9 Air and Heat 9 Diagrams 11 Center of Gravity 21 1C7070 3 ...

Page 4: ...BLANK PAGE 4 1C7070 ...

Page 5: ... 1C7061 1C7070 246626 246628 246629 Part No Publications for M6B Processors Serial Numbers 10 000 to 14 999 Complete Operator Installation Service Binder Manual Site Specs Instructions Manual Parts List Publication 635881 1C7061 1C7070 635884 635885 635882 Part No Publications for M6B Processors Serial Numbers Below 10 000 Complete Operator Installation Service Binder Manual Site Specs Instruction...

Page 6: ...60 in 123 2 cm 48 5 in Weight Tanks Empty 223 2 kg 492 lb 201 kg 442 lb Weight Tanks Full Not Applicable 235 kg 519 lb Approximate Solution Height Not Applicable 107 2 cm 42 5 in from the Base of the Processor Table 2 Maintenance and Operation Access Requirements Description Recommendation Dryer End of Processor 91 4 cm 36 in Feed End of Processor 91 4 cm 36 in Drive Side of Processor 91 4 cm 36 i...

Page 7: ...the processor in the lighted area easily accessible from the processor site visible from the processor site IMPORTANT Standard Service Options In addition all electrical services including earth ground must comply with local and national electrical codes Table 3 Service Options Voltage Frequency Service Volts Hz 100 200 50 60 Single phase 3 wire 120 208 60 Three phase 3 wire Wye 120 240 60 Single ...

Page 8: ...ied with the processor b Water service must comply with local codes c Tempered water service is suggested for processor cleaning and for mixing chemicals manually d A molded adapter and washer are provided to adapt the processor garden hose fitting to the 1 2 in NPT male Drain Drains must be made of chemically resistant non corrosive material Use PVC or the equivalent The drain must have a minimum...

Page 9: ...vent the dryer exhaust can cause corrosion within the processor and interfaced equipment In addition the probability of processor related film artifacts is increased 1 The processor exhaust duct must be connected to the building exhaust ducting system Disposal of effluent air must comply with prevailing environmental codes 2 The following table should be used to determine the proper amount of nega...

Page 10: ...ovided with the Air Meter can then be inserted through the opening When measuring negative air the tube tip opening should be pointed in the direction of airflow away from the processor IMPORTANT The processor must be turned off when making air measurements The Air Meter should be held in the vertical position to assure the greatest accuracy The meter tubing must not be kinked 5 It is most importa...

Page 11: ...EXHAUST FEED TRAY and SHELF WATER DRAIN VALVE WASH OVERFLOW and DRAIN FIXER OVERFLOW and DRAIN DEVELOPER OVERFLOW and DRAIN BUZZER WATER INLET U S GARDEN HOSE CONNECTOR FIXER DRAIN VALVE DEVELOPER DRAIN VALVE REPLENISHER TUBING INLETS from REMOTE TANKS AUXILIARY CIRCUIT BREAKERS RUN SWITCH RUN SWITCH Figure 2 Feed End View of the Processor 1C7070 11 ...

Page 12: ...iew of the Processor H048_0025BA H048_0025BCC DRYER TEMPERTURE CONTROL DRYER INDICATOR LAMP DEVELOPER TEMPERATURE METER DEVELOPER INDICATOR LAMP FIXER REPLENISHMENT FLOAT DEVELOPER REPLENISHMENT FLOAT REPLENISHMENT SWITCH Figure 4 Display Panel on Receiving End of the Processor 12 1C7070 ...

Page 13: ...6 mm 23 25 in 590 mm 63 mm 2 50 in 248 mm 9 75 in Leveling Feet Center To Center Distance Of 27 00 in 686 mm 121 mm 4 75 in 57 mm 2 25 in 13 25 in 425 mm 14 25 in 362 mm 48 50 in 1232 mm 57 mm 2 25 in 7 75 in 196 mm 3 12 in 77 mm 3 25 in 83 mm 7 75 in 196 mm 762 mm 30 00 in Figure 5 Feed End Dimensions of the Processor 1C7070 13 ...

Page 14: ...CRIPTION DIMENSION 14 GAL 30 GAL 55 GAL Max Platform Height A Fig 14 48 3 cm 19 in 35 6 cm 14 in 15 2 cm 6 in Tank Diameter B Fig 14 43 2 cm 17 in 55 9 cm 22 in 61 0 cm 24 in Tank Height C Fig 14 58 4 cm 23 in 70 5 cm 27 75 in 90 8 cm 35 75 in External Replenishment D x E 61 0 X 127 0 cm 61 0 x 152 4 cm 66 0 x 172 7 cm Tank Area MIN Fig 15 24 X 50 in 24 x 60 in 26 x 68 in 14 1C7070 ...

Page 15: ... Maintenance and Operation Access Requirements Description Recommendation Receiving End of Processor 91 4 cm 36 in Feed End of Processor 91 4 cm 36 in Drive Side of Processor 91 4 cm 36 in Non Drive Side of Processor 91 4 cm 36 in Top of Processor 91 4 cm 36 in 1C7070 15 ...

Page 16: ...REA 121 9 cm 48 0 in minimum 38 1 cm 15 0 in 5 1 cm 2 0 in 112 1 cm 44 in 7 6 cm 3 0 in LIGHT TIGHT GASKET compress to approx 1 0 cm 38 in upon installation ENTRANCE ROLLER ASSEMBLY DRYER EXIT ROLLERS 50 8 cm 20 0 in 49 5 cm 19 5 in Center to Center Distance of Leveling Feet 3 8 cm 1 5 in FLOOR H048_0090DA Figure 8 Side Dimensions 16 1C7070 ...

Page 17: ...lectrical and Water Connections NOTE Pass service through the wall to the feed end of the processor in the darkroom Service controls may be located on either side of the processor for easy accessibility See the Table on page 18 1C7070 17 ...

Page 18: ... 2 in NPT Two additional required Available from Eastman Kodak Company Part No 459981 Not supplied with the Processor E Cold Water Supply 1 2 in NPT F 30 AMP 2 POLE Thermo magnetic Circuit Breaker Locate safe distance from water service Not supplied with the Processor G Shutoff Valves 1 2 in NPT Two additional required Available from Eastman Kodak Company Part No 459981 H Hot and Cold Water Supply...

Page 19: ...l around the opening is straight and exactly perpendicular to the floor this panel may not be necessary The wall opening dimensions should match the inside dimensions of the panel opening B Make sure that the vertical dimension of 48 1 16 in for the wall opening is measured from the finished floor 1C7070 19 ...

Page 20: ...H048_0091AA H048_0091ACA Inlets for Replenishment Tubing Figure 11 Inlets for Replenisher Tubing H048_0006DA Figure 12 Alternate Inlets for Replenisher Tubing 20 1C7070 ...

Page 21: ... in W 38 8 cm 15 29 in H 72 2 cm 28 43 in 76 2 cm 30 0 in 57 2 cm 22 5 in Center of Gravity with TANKS empty H048_0117DA Figure 13 Center of Gravity NOTE Center of gravity is shown for the processor with the DEVELOPER FIXER and WASH TANKS empty 3040SS_B TXT 1C7070 21 ...

Page 22: ...3040SS_B TXT Kodak and X Omat are trademarks Health Sciences Division EASTMAN KODAK COMPANY ROCHESTER N Y 14650 Printed in USA ...