Operation 23
T.D. Thermo — Transverse Direction or Side Seal Temperature Control
Set the temperature for the side hot knife seal using the
“T.D. Thermo” temperature controller. This temperature
controller operates same as the front seal temperature
controller.
•
Press the first button to set the temperature.
•
Press the < button to select the digit to change. The
selected digit will blink.
•
Press the Up or Down direction arrows to increase or
decrease the value of the selected digit.
Seal Time
Use the “Seal TIME” timer to set the seal time. The seal time is the amount of time that
the magnets will hold the seal head down on the film. The seal time may vary according
to the type of film in use.
When the seal bar frame is pressed down onto the film, it will
remain in position for the set time then automatically release. Do
not hold the seal bar down onto the film.
Ensure that the timer sliding switches are in the times one (X1)
and the second (Sec) positions. If the timing switches are in the
X10 and or the minute positions it will result in a value that is far
outside of the desired operating range.
Attention!
Move the “Seal TIME” switch in very small
increments.
Take Away Time
Use the “Take-away TIME” to set the amount of time the conveyor will run.
When the seal bar is released the conveyor will automatically
move the product into the shrink tunnel according to the set time.
The takeaway time will vary according to the product being sealed
and the operator’s ability.
Ensure that the timer sliding switches are in the times ten (X10)
and the second (Sec) positions. If the timing switches are in the
X1 and or the minute positions it will result in a value that is far
outside of the desired operating range.