background image

Introduction 

The CFM/CMM Thermo Anemometer instrument measures Air Velocity, Air Flow 
(volume) and Temperature. The large, easy-to-read backlit LCD includes primary and 
secondary displays plus numerous status indicators. The meter is shipped fully tested 
and calibrated and with proper use will provide years of reliable service. 

 

Meter Description  

 

 

 

1. LCD 

Display 

2. Vane 
3. Rubber 

Boot 

4. Meter 
5. Power 

On/Off 

6. Area 
7. AVG 
8. Backlight 
9. Temperature 

Buttons 

10. Airflow/Velocity 

Buttons 

 
 

Keypad 

 

AUTO POWER OFF

       Press to turn the meter ON or OFF 

 

MAX/MIN

 Used to record and store the highest, lowest and average airflow or 

velocity readings. 

 (LEFT) also serves as change decimal point button in AREA mode 

 

UNITS 

Press to select the mode of operation. In FLOW mode, the meter displays 

air 

volume

. In VELOCITY mode, the meter displays air 

speed

.  

(UP) also serves as increase number button in AREA mode. 

 

AVG

 Used to Average multiple readings in FLOW or VELOCITY mode. Up to 20 

readings can be averaged.  

 

HOLD

 Press to freeze the displayed reading. Press again to unlock display. This 

button also functions as the 

RIGHT scroll button in AREA mode and RECALL 

mode. 

 

AREA

 Press and hold to manually enter the area of a duct in CFM or CMM mode 

 

NEXT

 In AREA mode, used to select memory locations 1-8.  

 

      Press to turn the backlight on/off 

 

MAX/MIN (Temperature)

 Used to record and store the highest, lowest readings for 

air temperature. 

 

°C °F HOLD (Temperature)

 Press to freeze the displayed temperature reading. 

Press again to unlock the display. Press and hold for 3 seconds to switch between 
°C and °F. Meter will beep twice to indicate change.

 

Battery compartment located on the back of the instrument. The rubber protective jacket 
must be removed from the meter to access the compartment. 

 

Eastern Energy Co., Ltd.

 

40/4 Vitoondumri Rd., Banbueng

   

Banbueng, Chonburi, Thailand

 

 

Tel: 66-3844-6117

[email protected]

www.eastern-energy.com

www.eastern-energy.net

Summary of Contents for DT-619

Page 1: ...User s Manual CFM CMM Thermo Anemometer Model DT 619 Eastern Energy Co Ltd 40 4 Vitoondumri Rd Banbueng Banbueng Chonburi Thailand Tel 66 3844 6117 sale ete co th www eastern energy com...

Page 2: ...e number button in AREA mode AVG Used to Average multiple readings in FLOW or VELOCITY mode Up to 20 readings can be averaged HOLD Press to freeze the displayed reading Press again to unlock display T...

Page 3: ...rature units of measure CFM CMM airflow units of measure Ft 2 m 2 units for area dimensions m s ft min km h MPH knots air velocity units of measure X10 X100 multipliers for air flow readings AVG air a...

Page 4: ...he LCD Display The large main LCD display shows the Air Velocity reading The upper right LCD sub display shows the temperature reading Air Velocity Averaging Mode 1 To enter 20 Point Averaging Mode pr...

Page 5: ...the desired location Once you have selected the desired memory location enter your dimension Use the UP button to change the flashing digit Use the LEFT button to move the decimal Use RIGHT button to...

Page 6: ...rrent readings NOTE the meter will keep recording MAX MIN AVG readings 5 To clear and stop MAX MIN AVG recording and return to normal operation press and hold the MAX MIN button until the meter beeps...

Page 7: ...g per second approx Sensors Air velocity flow sensor Conventional angled vane arms with low friction ball bearing Temperature sensor NTC type precision thermistor Automatic Power off Auto shut off aft...

Page 8: ...x Area ft2 NOTE Measurements made in inches must be converted to feet or meters before using the above formulae Unit of Measure Conversion Table m s ft min knots km h MPH 1 m s 1 196 87 1 944 3 6 2 2...

Reviews: