Eastern Energy 840063 Instruction Manual Download Page 3

 

- 3 - 

II.   PANEL DESCRIPTION 

(fig. A)

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

III.  OPERATING INSTRUCTIONS 
 
A.  GENERAL MEASUREMENT PROCEDURES 

 
1.  Attached the 

BNC PLUG 

(A11) to the 

BNC SOCKET 

(A10). 

2.  Attached the 

MINI PLUG 

(A12)

 

to the 

INPUT SOCKET 

(A13). 

3.  a.  Acceleration (ACC) Measurement:  
 

Switch the 

ACC/VEL SELECTOR 

(A7) to the "ACC" position. 

 

b. Velocity (VEL) Measurement: 

 

Used for general industrial vibration.  Switch the 

ACC/VEL 

 

SELECTOR 

(A7) to the "VEL" position.  

4.  Switch the 

RMS/PEAK SELECTOR 

(A4) to the "RMS" position. 

5.  Press the 

POWER BUTTON 

(A2) once to turn on the meter. 

1.  DISPLAY 
2.  POWER BUTTON 
3.  HOLD BUTTON 
4.  RMS/PEAK SELECTOR 
5.  RECORD BUTTON 
6.  RECALL BUTTON 
7.  ACC/VEL SELECTOR 
8.  BATTERY COVER 

 
  9.  RS232 OUTPUT TERMINAL 
10.  BNC SOCKET 
11.  BNC PLUG 
12.  MINI PLUG 
13.  INPUT SOCKET 
14.  VIBRATION SENSOR 
15.  MAGNETIC BASE 

 

 
 
 
 
 

 

11 

 
 

 
 
 
 
 
 

 

12 
 

 

13 
14 
 
 
 
15 

10 
 
 
 

 
 




 
 
 
 
 
 

www.eastern-energy.net

Email: [email protected]

www.eastern-energy.net

Summary of Contents for 840063

Page 1: ...VIBRATION METER 840063 Instruction Manual www eastern energy net Email info ete co th...

Page 2: ...vibration is a useful guide to the balance alignment and gen eral condition of pumps motors and other machinery Poor balance mis alignment and looseness results in higher levels of vibration and indic...

Page 3: ...dustrial vibration Switch the ACC VEL SELECTOR A7 to the VEL position 4 Switch the RMS PEAK SELECTOR A4 to the RMS position 5 Press the POWER BUTTON A2 once to turn on the meter 1 DISPLAY 2 POWER BUTT...

Page 4: ...non magnetic material hold the VIBRATION SENSOR and touch the tip to the object above b If the surface material is magnetic connect the VIBRATION SENSOR to the MAGNETIC BASE left and touch it to the o...

Page 5: ...the RECORD BUTTON A5 for approximately 2 seconds The display will revert back to the current reading E AUTOMATIC SHUT OFF This unit has a built in automatic shut off function to prolong battery life T...

Page 6: ...e are 4 different machine groups with 4 classification ranges and DO End Word D1 to D4 Upper Display reading D1 LSD D4 MSD D5 to D8 All D9 Decimal Point DP position from right to the left 0 No DP 1 1...

Page 7: ...ill permissible 4 51 11 2 mm s Dangerous 11 2 mm s GROUP T Largest machines and turbo machines with special foundations Good 0 2 80 mm s Acceptable 2 81 7 10 mm s Still permissible 7 11 18 0 mm s Dang...

Page 8: ...computer circuit V WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of one 1 year from the date of purchase and agrees to repair or replace any...