background image

14

REMARKS

1. Please contact manufacturer or agent to maintain the malfunction that cannot be
confirmed and removed, don’t disassemble the machine by yourself
2. It will produce noise when the dehumidifier power on or power off, it’s normal.
3. It will produce heat wind at the air outlet, it’s normal

MALFUNCTIONS

ANALYZE

REMOVAL

DEHUMIDIFIER IS

NOT WORKING

1. POWER FAILURE

2. POWER OFF

3. POWER IS NOT PLUG IN

4. BLOWN FUSE

1. RESUME POWER

2. POWER ON

3. PLUG IN

4. REPLACE FUSE

BAD

DEHUMIDIFICATION

EFFECT

1. FILTER BLOCKED WITH DUST

2. AIR INLET IS BLOCKED

3. USED IN BAD SEALED ROOM

4. LESS REFRIGERANT

1. WASH FILTER

2. REMOVE BLOCK

3. CLOSE DOOR AND

WINDOWN

4. FILL REFRIGERANT OR

CONTACT WITH

MANUFACTURER

LEAKAGE

1. MACHINE IS NOT

HORIZONTAL

2. DRAIN TUBE IS BLOCKED

1. PLACE THE MACHINE

HORZONTAL

2. WASH OR CHANGE THE

TUBE

NOISE

1. MACHINE IS NOT INSTALLED

STABLE

2. FILTER BLOCKED

1. PLACE THE MACHINE

STABLE

2. WASH THE FILTER

NORMA MALFUNCTION REMOVAL

Summary of Contents for SDT-150L

Page 1: ...1 GROW ROOM DEHUMIDIFIER SDT 150L INSTRUCTION MANUAL ...

Page 2: ...ge Exclusively grow room designed dehumidifiers 1 All metal plate framed structure shell 2 Separated electrical box for easily maintaining 3 Low voltage control 4 Opposite air inlet and outlet to reduce efficiency interference 5 Duct kits as optional accessories can be easily connected 6 Long life brushless direct drive fan Noise 50 lower 7 Memory function of operating mode after power outages 8 H...

Page 3: ...3 SAFTY INSTRUCTIONS 4 SPECIFICATIONS 5 UNPACKING THE DEHUMIDIFIER 6 INSTALLATION GUIDE 8 OPERATION GUIDE 10 EXTERNAL CONTROLLER 12 NORMAL MALFUNCTION REMOVAL 14 DIRECTORY ...

Page 4: ... s not necessary to use dehumidifier when the room temperature is below 10 the absolute humidity is quite low at this condition 5 Please try to seal environment better to increase the effect of dehumidifier 6 Do not place the machine in the area which may come into contact with water or chemical 7 Do not use any relay extension line or adapter to connect the power of machine 8 Do not place the mac...

Page 5: ...ight 134 lbs without packaging Drain Size 5 8 Capacity 320 Pints 86 F 80 RH Airflow 790 CFM free flow ELECTRICAL Voltage 208 230 VAC 1ø 60 HZ Operating Current 7 0A 86 F 80 RH Efficiency 86 F 80 RH 5 2 L kW hr 11 1 pints kW hr 86 F 80 RH Efficiency 80 F 60 RH 3 13 L kW hr 6 67 pints kW hr 80 F 60 RH SPECIFICATIONS ...

Page 6: ...and remove the protection film to take out the dehumidifier for installation WHAT S IN THE CASE Dehumidifier controller Drain tube Filter Instruction manual Power cord Technical label UNPACKING THE DEHUMIDIFIER STRUCTURE AND RUNNING ...

Page 7: ... automatically when freezing occurs While defrosting the compressor will not work but the brushless fan will continue to run in order to melt the ice on coil inside Defrosting light will be on Dehumidifier will start automatically once defrost process is complete Default defrost settingoccurswhen ambient temperature is under 15 Compressor delay start protection function Manual restart of system wi...

Page 8: ...o the position of install hole on the machine then install the expansion screw to fix the thread rod B Install dehumidifier through the four thread rods and adjust the height according the space to ensure the machine on horizontal level C Connect the drain tube to make sure no leakage no block in the drainage tube D Connect power please make sure the power supply is 208 240v 60hz And the overload ...

Page 9: ...ews to fix the dehumidifier on the ceiling 3 Ensure the installation of dehumidifier is horizontal to avoid malfunction or leakage 4 Ensure drain tube is installed unhindered without overmuch bends 5 Ensure dehumidifier is installed within space with proper air circulation for air inlet and air outlet it is prohibited to install at corner or space with obstructions what block the inlet or outlet ...

Page 10: ...ed with a little diluted neutral detergent 3 Filter Cleaning it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter it needs to be cleaned regularly clean it at least once a month Use dust catcher to remove dust or put filter into clean water 40 to wash then place filter back after cleaning NOTE The filter cannot be put in sunlight directly or roasted to avoid di...

Page 11: ... ambient humidity when in standby or dehumidifying mode Setting mode will automatically become to dehumidifying mode after 5 seconds without pressing any button 5 The dehumidifying mode symbol will on when compressor is working The dehumidifying mode symbol will blink if the compressor in 3 minutes delay protection 6 Press mode button to switch ventilation mode if you want only fan to run The vent...

Page 12: ... 3 dehumidification for both fan and compressor control 4 24V power 5 fan control 6 24v power Common The 4 and 6 terminal will provide 24V DC with 40VA This 24V DC power source can be used for both 24V DC and AC controller Controller SDT 24DA is provided with dehumidifier SDT 24DA wiring EXTERNAL CONTROLLER ...

Page 13: ...13 HS 1 wiring Other 3rd party controller wiring ...

Page 14: ... 2 POWER OFF 3 POWER IS NOT PLUG IN 4 BLOWN FUSE 1 RESUME POWER 2 POWER ON 3 PLUG IN 4 REPLACE FUSE BAD DEHUMIDIFICATION EFFECT 1 FILTER BLOCKED WITH DUST 2 AIR INLET IS BLOCKED 3 USED IN BAD SEALED ROOM 4 LESS REFRIGERANT 1 WASH FILTER 2 REMOVE BLOCK 3 CLOSE DOOR AND WINDOWN 4 FILL REFRIGERANT OR CONTACT WITH MANUFACTURER LEAKAGE 1 MACHINE IS NOT HORIZONTAL 2 DRAIN TUBE IS BLOCKED 1 PLACE THE MAC...

Page 15: ...15 EAST dehumidifier manufacturer Room 1603 1604 Yifeng Times Mansion Hangzhou China 311113 Phone 8613685770742 WhatsApp 8613685770742 Skype tiger19840517 https www eastdehumidifier com ...

Reviews: