ET5301/5302/5303/5304 Programmable DC Electronic Load User Manual 

Hangzhou Zhongchuang Electronics Co., Ltd. 

 

 

2.3 Load Setup 

Load setup interface can be entered through the system menu, as shown in figure 2.3.The load range, 

limit value, off-delay and other related settings can be completed in this interface.

 

Operating instructions: 1. Select the 

operation option

 by turning the knob. 2. Press

Enter

to switch 

set options for non-numeric parameters.

 

3. As for the setting of numeric parameters, please refer to 1.4 

Numeric Parameter Setting for details. 4. Press

Esc

to return to the previous interface. 

 

 

Figure 2.3 Load setup interface

 

2.4 Basic mode 

 

Electronic load can work in the following basic measurement modes: constant current mode (CC), 

constant voltage mode (CV), constant resistance mode (CR), constant power mode (CP), constant current 

to constant voltage mode (CC+CV), constant resistance to constant voltage mode (CC+CR). The 

parameter settings for the above six modes can be done in the measurement interface. In addition, press 

[Mode] on the main interface of any mode to enter the mode selection interface, as shown in figure 2.4. 

 

Operating instructions: 1

 

Select the action item by turning the knob. 2. Press

Enter

to confirm the 

selected mode. 3. Press

Esc

to return to the previous interface. 

 

MEAS  DI SP

CC

  10. 000
   

1.000

Set :

  1. 000

Of f   Ti me:

  10000  S

Li mi t :

15. 000  V
  3. 000  A
220. 00  W

V

A

W

    10. 00

A

02. CV

01. CC

04. CR

03. CP

06. CR+CV

05. CC+CV

08. LI ST

07. TRAN

10. SHORT

09. SCAN

12. LED

11. B

ATTERY

01. CC

 

Figure 2.4 Mode selection interface

 

2.4.1 Constant current mode 

In constant current mode, the electronic load consumes a constant current regardless of whether the 

input voltage changes or not.

 

Operating instructions: 1

 

Select the operation option by turning the knob. 2. For parameter settings, 

please refer to 1.4 Numeric Parameter Setting for details. 3. Press the corresponding

On/Off

  to turn on 

the load.. 

Summary of Contents for ET5300

Page 1: ...ET5300 5301 5302 5303 Programmable DC Electronic Load User Manual Hangzhou Zhongchuang Electronics Co Ltd...

Page 2: ...Hangzhou Zhongchuang Electronics Co Ltd Adress NO 3 Kangle Road Gongshu District Hangzhou China Postcode 310015 Telephone 0086 571 56861333 Fax 0086 571 56861355 Website http www east tester com...

Page 3: ...ower output within a certain range Support 4 wire measurement The list test mode can simulate a variety of loading status changes The short circuit test can be used to simulate load short circuit Supp...

Page 4: ...tant power mode 6 2 4 5 Constant current to constant voltage mode 6 2 4 6 Constant resistance to constant voltage mode 6 2 5 Tran Test 7 2 6 List Test 8 2 7 Scan Test 11 2 8 Battery Test 12 2 9 LED Te...

Page 5: ...e 10000 S Li m i t 15 000 V 3 000 A 220 00 W V A W 10 00 A Icon bar there are five types of icons on the electronic load interface 1 2 Front panel key Range V 1 2 3 Mode 4 5 6 Enter 7 8 9 Local 0 ESC...

Page 6: ...s cannot be used Local For switching to the local mode Trigger Trigger key for manual trigger Keys used for moving the cursor left or right Range I Shortcut key for current range switching Range V Sho...

Page 7: ...n remote operation mode the corresponding icon will be displayed on the top of the interface At this time the interface is locked and the status and operation of the instrument can be controlled throu...

Page 8: ...CC CV constant resistance to constant voltage mode CC CR The parameter settings for the above six modes can be done in the measurement interface In addition press Mode on the main interface of any mod...

Page 9: ...r details 3 Press the corresponding On Off to turn on the load M EAS D I SP C V 0 000 0 000 Set 16 000 O f f Ti m e 10000 S Li m i t 15 000 V 3 000 A 220 00 W V A W 0 00 V Figure 2 4 2 Constant voltag...

Page 10: ...current to constant voltage mode is to prevent the source to be measured from being damaged by overcurrent discharge In this mode when the source to be measured cannot output the current value set by...

Page 11: ...rrents or voltages set by the load This function can be used to test the dynamic characteristics of the power source Moreover the Tran test is divided into three modes continuous mode pulse mode and t...

Page 12: ...mated testing of production line Preset the steps of the list test and then edit the test steps and test parameters of the source to be measured into a list and complete a series of tests in sequence...

Page 13: ...ion key to select save and then press Enter to enter the list test parameters saving interface as shown in figure 2 6 4 Please refer to the operating instructions for list test parameters saving inter...

Page 14: ...rface 1 Select the file by turning the knob 2 Press direction keys to switch to the edit state before any file can be edited Press the direction key to select the previous or next page and then press...

Page 15: ...igure 2 6 7 File rename interface 2 7 Scan Test Scan test can be used to detect the continuous working conditions of the source to be measured within a certain range and makes it easy to capture vario...

Page 16: ...to measure the discharge capacity of the battery Operating instructions 1 Press Menu in the main interface of battery test to enter the battery parameters setting interface 2 Select the action item b...

Page 17: ...ng the knob 2 For parameter setting please refer to 1 4 Numeric Parameters Setting for details 3 Press On Off to turn on or off the mode Option Description Name content Description LED Vo 0 Vmax Stead...

Page 18: ...rature protection and reverse polarity prompt the prompt information is subject to the real picture M EAS D I SP C C 0 000 0 000 Set 3 000 O f f Ti m e 10000 S Li m i t 15 000 V 3 000 A 220 00 W V A W...

Page 19: ...rted 2 15 Other system settings 2 15 1 Key Lock Function The load also added the lock function to prevent user misoperations The title bar will display the lock identifier In the lock out state all th...

Page 20: ...eness F1 The list test result is unqualified low effectiveness G GND Expansion port input N1 External trigger input The extension port output is OC gate output The user needs to connect the pull up re...

Page 21: ...ange 0 400W Resolution 10mW Accuracy 0 1 0 5 FS Tran Test Mode CC CV T1 T2 50ms 60s Battery Test Accuracy CC CR Discharge mode 9999Ah Maximum discharge capacity 1mA 10mA 10m 100m Range of measurement...

Page 22: ...Resolution 10mW Accuracy 0 1 0 5 FS Tran Test Mode CC CV T1 T2 50ms 60s Battery Test Accuracy CC CR Discharge mode 9999Ah Maximum discharge capacity 1mA 10mA 10m 100m Range of measurement Voltage read...

Reviews: