ZIP WATER PURIFIER USER GUIDE
10
Replace the post filter retaining clips back onto the RO cartridge and replace the post filter into
the re
taining clips (fig 10)
11
Replace the back cover (fig 11 and 12)
TROUBLESHOOTING
SYMPTOM
CAUSE
SOLUTION
ZERO PRODUCTION
No water in the lower reservoir
Fill tank
No power
Check power supply
Lower reservoir misplaced
Ensure that the lower reser-
voir is positioned properly
PRODUCTION LIMITED
Inner tube pinched
Check and repair
Water to be treated is outside the
operating range
Check the quality of the water
to be treated
FILTERING WONT START
No water in the lower reservoir
Fill reservoir
No power
check power supply
Lower reservoir misplaced
Ensure the lower reservoir is
positioned properly
LED off
Transformer is disconnected or
defective
Make sure the transformer is
correctly attached
Page 15 (final)