USER MANUAL, MSD-4, PT# 101012 

P a g e

 | 

2

 

EAST COAST DATACOM, INC. 

 

1.2

      

THEORY

 

OF

 

OPERATION

 

 

In a polled or contention environment the typical MSD operation is as follows: 
Data arriving at the MSD's master port is continually broadcast to all of the MSD-4 sub-channel 

ports.  When one of the DTE devices answers the poll from the host site, that DTE device will 
raise RTS (Request To Send).  When RTS is raised the MSD-4 scanner circuitry will lock on to that 

port and allow that attached DTE device to communicate with the modem link.  The MSD will 
remain locked onto that port until RTS is dropped and CTS (Clear To Send) is dropped from the 

modem.  After RTS and CTS have dropped, the MSD will automatically begin scanning the ports 
until another port raises RTS. 

OPTIONALLY: The “OR-MODE” of operation may be selected and the contention mode with  any 
DTE device that the DATA lead transitions from Mark to Hold will have access to the Master 

Port.(the user system software must only allow one device at a time communicate) 

CHAPTER 2 - BASIC OPERATION AND FUNCTIONS 

 

2.1

      

FRONT

 

PANEL

 

INDICATORS

 

AND

 

SWITCHES

 

 

Green

 LED illuminates when AC Power has been applied.  Four adjacent 

Green

 LEDs illuminate   

and identify CTS, DCD, RXD and TXD on the Master Ports RS-232 signal status.  Sub-channel Ports 
A thru D Active LED’s are also green and only one of the four LED’s will ever illuminate at a single 

time, when a sub-channel is active. Yellow LEDs are provided as a visual indication of a 
streaming sub-channel, the LEDs illuminate only if anti-streaming is enabled.   

 

2.2

      

FRONT

 

PANEL

 

SWITCHES

 

 

Positive latching switches are provided for each sub-channel Port A thru D for isolating or 
removing attached terminals.  To disable a sub-channel simply push the switch, so it is in the 

outer most position. 

NOTE:

 The switch disables the ability of the sub-channels Pin 2 TXD to 

transmit back to the Master Port. Pin 3 RXD from the Master Port is always sent out to all sub-

channels. This feature is by design for data broadcast applications and data is always outbound. 

 

2.2

      

REAR

 

PANEL

 

CONNECTORS

 

AND

 

FUSES

 

 

Located on the rear of the product you will find an IEC Power Receptacle.  The supplied power 
cord plugs into this receptacle.  This receptacle also contains a fuse drawer.   

 

2.3

      

CLOCKING

 

The MSD-4 derives clocking from the attached Modem or DCE. 
 

2.4

      

ELECTRICAL

 

INTERFACE

 

The MSD-4 is EIA RS-232 (CCITT V.24) compliant using female DB-25 connectors.   

 

 

Summary of Contents for 101012

Page 1: ...m Sharing Device Ordering Part Number 101012 Manufactured By East Coast Datacom Inc FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 245 Gus Hipp Blvd STE 300 Rockledge FL 32955 U S A TEL 321 637 9922 Email support ecdata com Web Address www ecdata com Publication 719008 Rev A ...

Page 2: ...7 2 Manual DTE Removal 4 2 7 3 Unexplained Streaming Terminals 4 2 8 Dial Modem Support 4 2 9 Cascading or Concatenation 4 CHAPTER 3 INSTALLATION 4 3 1 Voltage Selection 4 3 2 Voltage Selection Fuses 4 3 3 Power Connection 5 3 4 INTERNAL DIP SWITCH AND PIN HEADER SETTINGS 5 3 4 1 SW1 Dip Switch Settings 5 3 4 1 2 Anti Streaming SW1 4 5 3 4 2 2 Channel Service Modes SW1 5 5 3 4 2 3 Frame to Signal ...

Page 3: ...nformation contained herein is proprietary to East Coast Datacom Inc Any reproduction or redistribution of this publication in whole or in part is expressly prohibited unless written authorization is provided by East Coast Datacom Inc WARRANTY NOTICE WARRANTIES East Coast Datacom Inc hereafter referred to as E C D warrants that its equipment is free from any defects in materials and workmanship Th...

Page 4: ...hannels The user is presented with two modes of operation for terminal access The first mode is the attached terminal device s that raises the RTS control signal is automatically given control of the MSD channel until data transmission is complete The second mode is the attached terminal device s that transition data from Mark to Hold is automatically given control of the MSD until data transmissi...

Page 5: ...uminates when AC Power has been applied Four adjacent Green LEDs illuminate and identify CTS DCD RXD and TXD on the Master Ports RS 232 signal status Sub channel Ports A thru D Active LED s are also green and only one of the four LED s will ever illuminate at a single time when a sub channel is active Yellow LEDs are provided as a visual indication of a streaming sub channel the LEDs illuminate on...

Page 6: ...ub channels can communicate back to the host at the same time 2 6 DATA BROADCAST ONLY APPLICATIONS The MSD 4 may be used in Data Clock Broadcast applications This can be accomplished by several methods One Disable the Front Panel switches and RXD and Clock from the Master Port will always continue outbound to all sub channels And data cannot be sent back to the Master Port Two Remove Pin 2 TXD fro...

Page 7: ...r long unterminated cables 2 8 DIAL MODEM SUPPORT The MSD 4 support dial modem applications by connecting the DTR jumper pin for each DTE port The jumper pin enables disables the DTR signal to each DTE sub channel If a dial modem is used with terminals all DTR jumpers must be enabled JP15 JP 18 2 9 CASCADING OR CONCATENATION The MSD 4 supports cascading and the user simply needs to use DB 25 Male ...

Page 8: ...ip Switches SW1 1 4 as shown in the chart below To Disable Anti Streaming set dip switches SW1 1 4 all to the OFF position Anti Streaming Time out SW 1 SW 2 SW 3 SW 4 Time Sec OFF OFF OFF ON 0 02 ON OFF OFF ON 0 04 OFF ON OFF ON 0 08 ON ON OFF ON 0 3 OFF OFF ON ON 1 ON OFF ON ON 5 OFF ON ON ON 20 ON ON ON ON 40 OFF OFF OFF OFF Disabled 3 4 2 2 Channel Service Modes SW1 5 Dip Switch position SW1 5 ...

Page 9: ...2 3 Pass Normal JP6 RTS Master Port Operation 1 2 RTS to Master is forced ON 2 3 Normal RTS to Master port Any Sub channel port RTS gives RTS to master JP7 DTR Master Port Operation 1 2 DTR to Master is turned ON if any DTR from User ports is turned ON 2 3 DTR to Master is for forced on 3 7 SUB CHANNEL PORT OPTIONS JP1 JP2 JP3 JP4 CTS Sub Channel Control per port control 1 6 CTS to user port follo...

Page 10: ...USER MANUAL MSD 4 PT 101012 P a g e 7 EAST COAST DATACOM INC OVERVIEW MSD 4 PCB SWITCH SETTINGS Figure 2 PCB OVERVIEW MSD 4 ...

Page 11: ...F Receive Line Detector X 15 114 DB Send Timing X 17 115 DD Receive Timing X 20 108 2 CD Terminal Ready X 22 125 CE Ring Indication X 24 113 DA External Timing X SUB CHANNEL PORT IS A DCE Connect to a DTE Pin No CCITT Circuit Circuit Name Signal Description To DTE To DCE 1 Shield 2 103 BA Send Data X 3 104 BB Receive Data X 4 105 CA Request To Send X 5 106 CB Clear To Send X 6 107 CC DCE Ready X 7...

Page 12: ...USER MANUAL MSD 4 PT 101012 P a g e 9 EAST COAST DATACOM INC OVERVIEW MSD 4 FRONT AND REAR VIEWS Figure 3 FRONT REAR VIEWS MSD 4 ...

Page 13: ...2 13 inches 30 810 CM Length 11 13 inches 28 270 CM Weight 6 pounds 2 72Kg Warranty Three Years Return to Factory MTBF 601 328 Hours Benign Ground Controlled Telcordia Issue 1 Approvals EMI Safety Environmental EMI Approvals FCC 47CFR Part 15 Subpart B for conducted emissions from a Class A FCC 47CFR Part 15 Subpart B for radiated emissions from a Class A Safety Approvals UL 62368 1 ESD Electric D...

Reviews: