Always observe standard safety precautions during installation, operation and maintenance of this 
product.  To avoid the possibility of electrical shock, be sure to disconnect the power cord from the power 
source before you remove the IEC power fuses or perform any repairs. 

 

AVERTISSEMENTS

 

DE

 

SÉCURITÉ

 

 
Respectez toujours les précautions de sécurité standard lors de l'installation, du fonctionnement et de la 
maintenance de ce produit. Pour éviter tout risque de choc électrique, assurez-vous de débrancher le 
cordon d'alimentation de la source d'alimentation avant de retirer les fusibles d'alimentation CEI ou 
d'effectuer toute réparation. 

 

 

 
 

 

FCC

 

CLASS

 

A

 

INFORMATION

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation. 
 

Changes or modifications to this product not expressly approved by East Coast Datacom, Inc. 
could void the user's authority to operate the equipment.

 

PROPRIETARY

 

NOTICE

 

The information contained herein is proprietary to East Coast Datacom, Inc.  Any reproduction or 
redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization 

is provided by East Coast Datacom, Inc. 
 

WARRANTY

 

NOTICE

 

WARRANTIES:  East Coast Datacom, Inc. (hereafter referred to as E.C.D.) warrants that its equipment is 
free from any defects in materials and workmanship.  The warranty period shall be three (3) years from 
the date of shipment.  E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of 

defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period.  
This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made 
by E.C.D. or authorized by E.C.D. in writing. 
 

 

 

 

CAUTION:

 FOR CONTINUED PROTECTION FROM RISK OF FIRE, 

REPLACE ONLY WITH SAME TYPE AND RATING FUSE. 

ATTENTION:

 POUR UNE PROTECTION CONTINUE CONTRE LES 

RISQUES D'INCENDIE, REMPLACEZ UNIQUEMENT AVEC UN 
MÊME TYPE ET UN FUSIBLE DE QUALITÉ. 

CAUTION:

 

RISK

 

OF

 

ELECTRIC

 

SHOCK:

 GROUNDED CONDUCTOR (NEUTRAL) PROVIDED 

WITH OVERCURRENT PROTECTION. TEST COMPONENTS BEFORE TOUCHING. 

ATTENTION:

 

RISQUE

 

DE

 

CHOC

 

ÉLECTRIQUE:

 CONDUCTEUR MIS À LA TERRE (NEUTRE) 

ÉQUIPÉ D'UNE PROTECTION CONTRE LES SURINTENSITÉS. TESTEZ LES COMPOSANTS 
AVANT DE TOUCHER. 

Summary of Contents for 101012

Page 1: ...m Sharing Device Ordering Part Number 101012 Manufactured By East Coast Datacom Inc FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 245 Gus Hipp Blvd STE 300 Rockledge FL 32955 U S A TEL 321 637 9922 Email support ecdata com Web Address www ecdata com Publication 719008 Rev A ...

Page 2: ...7 2 Manual DTE Removal 4 2 7 3 Unexplained Streaming Terminals 4 2 8 Dial Modem Support 4 2 9 Cascading or Concatenation 4 CHAPTER 3 INSTALLATION 4 3 1 Voltage Selection 4 3 2 Voltage Selection Fuses 4 3 3 Power Connection 5 3 4 INTERNAL DIP SWITCH AND PIN HEADER SETTINGS 5 3 4 1 SW1 Dip Switch Settings 5 3 4 1 2 Anti Streaming SW1 4 5 3 4 2 2 Channel Service Modes SW1 5 5 3 4 2 3 Frame to Signal ...

Page 3: ...nformation contained herein is proprietary to East Coast Datacom Inc Any reproduction or redistribution of this publication in whole or in part is expressly prohibited unless written authorization is provided by East Coast Datacom Inc WARRANTY NOTICE WARRANTIES East Coast Datacom Inc hereafter referred to as E C D warrants that its equipment is free from any defects in materials and workmanship Th...

Page 4: ...hannels The user is presented with two modes of operation for terminal access The first mode is the attached terminal device s that raises the RTS control signal is automatically given control of the MSD channel until data transmission is complete The second mode is the attached terminal device s that transition data from Mark to Hold is automatically given control of the MSD until data transmissi...

Page 5: ...uminates when AC Power has been applied Four adjacent Green LEDs illuminate and identify CTS DCD RXD and TXD on the Master Ports RS 232 signal status Sub channel Ports A thru D Active LED s are also green and only one of the four LED s will ever illuminate at a single time when a sub channel is active Yellow LEDs are provided as a visual indication of a streaming sub channel the LEDs illuminate on...

Page 6: ...ub channels can communicate back to the host at the same time 2 6 DATA BROADCAST ONLY APPLICATIONS The MSD 4 may be used in Data Clock Broadcast applications This can be accomplished by several methods One Disable the Front Panel switches and RXD and Clock from the Master Port will always continue outbound to all sub channels And data cannot be sent back to the Master Port Two Remove Pin 2 TXD fro...

Page 7: ...r long unterminated cables 2 8 DIAL MODEM SUPPORT The MSD 4 support dial modem applications by connecting the DTR jumper pin for each DTE port The jumper pin enables disables the DTR signal to each DTE sub channel If a dial modem is used with terminals all DTR jumpers must be enabled JP15 JP 18 2 9 CASCADING OR CONCATENATION The MSD 4 supports cascading and the user simply needs to use DB 25 Male ...

Page 8: ...ip Switches SW1 1 4 as shown in the chart below To Disable Anti Streaming set dip switches SW1 1 4 all to the OFF position Anti Streaming Time out SW 1 SW 2 SW 3 SW 4 Time Sec OFF OFF OFF ON 0 02 ON OFF OFF ON 0 04 OFF ON OFF ON 0 08 ON ON OFF ON 0 3 OFF OFF ON ON 1 ON OFF ON ON 5 OFF ON ON ON 20 ON ON ON ON 40 OFF OFF OFF OFF Disabled 3 4 2 2 Channel Service Modes SW1 5 Dip Switch position SW1 5 ...

Page 9: ...2 3 Pass Normal JP6 RTS Master Port Operation 1 2 RTS to Master is forced ON 2 3 Normal RTS to Master port Any Sub channel port RTS gives RTS to master JP7 DTR Master Port Operation 1 2 DTR to Master is turned ON if any DTR from User ports is turned ON 2 3 DTR to Master is for forced on 3 7 SUB CHANNEL PORT OPTIONS JP1 JP2 JP3 JP4 CTS Sub Channel Control per port control 1 6 CTS to user port follo...

Page 10: ...USER MANUAL MSD 4 PT 101012 P a g e 7 EAST COAST DATACOM INC OVERVIEW MSD 4 PCB SWITCH SETTINGS Figure 2 PCB OVERVIEW MSD 4 ...

Page 11: ...F Receive Line Detector X 15 114 DB Send Timing X 17 115 DD Receive Timing X 20 108 2 CD Terminal Ready X 22 125 CE Ring Indication X 24 113 DA External Timing X SUB CHANNEL PORT IS A DCE Connect to a DTE Pin No CCITT Circuit Circuit Name Signal Description To DTE To DCE 1 Shield 2 103 BA Send Data X 3 104 BB Receive Data X 4 105 CA Request To Send X 5 106 CB Clear To Send X 6 107 CC DCE Ready X 7...

Page 12: ...USER MANUAL MSD 4 PT 101012 P a g e 9 EAST COAST DATACOM INC OVERVIEW MSD 4 FRONT AND REAR VIEWS Figure 3 FRONT REAR VIEWS MSD 4 ...

Page 13: ...2 13 inches 30 810 CM Length 11 13 inches 28 270 CM Weight 6 pounds 2 72Kg Warranty Three Years Return to Factory MTBF 601 328 Hours Benign Ground Controlled Telcordia Issue 1 Approvals EMI Safety Environmental EMI Approvals FCC 47CFR Part 15 Subpart B for conducted emissions from a Class A FCC 47CFR Part 15 Subpart B for radiated emissions from a Class A Safety Approvals UL 62368 1 ESD Electric D...

Reviews: