background image

- 10 -

Find the scale's

mark position (

)

ref

FIND REF

function :

In ref datum memory function, the

will automatically store the relative

distance between the

mark position and the work piece datum ( zero position )

whenever the operator alter the

zero position, such as zeroing, centre find,

co-ordinate preset or etc...

Therefore, the

needs to store the

mark position prior to any machining

operation. So that the loss of the work piece datum ( zero position ) is avoided during
any accidential or unexpected events, such as power failure or etc.. it is recommend that
the operator finds the ref mark position using the (

) function whenever

he switches on the

.

ES-3

ABS

ES-3

FIND REF

ES-3

ref

ref

step 3 :

move the machine reader head across the length of the transducer until digits display in ES-3
start to count.

move the machine across

the length of the transducer

move the machine

until

's digits

display start run

ES-3

RECALL 0

(recall work zero)

step 1 :

To enter the ref function, select the

( find

mark )

FIND REF

ref

step 2 :

select the axis of which

mark needs to be found

ref

enter

function

ref

select

axis

in this example

X

FIND REF

(find

mark)

ref

<

>

select the

(find

mark)

2-FIND REF

ref

2

select all axes :

respectively

X, Y, Z

select

axis

X, Y, Z

or

or

X

Y

Z

Easson

ES-3

CE

ent

1

2

3

4

5

6

7

8

9

+

_

.

0

ref

1/2

abs

inc

in

mm

X

0

Y

0

X

Y

Z

Z

0

1.250

Easson

ES-3

CE

ent

1

2

3

4

5

6

7

8

9

+

_

.

0

ref

1/2

abs

inc

in

mm

X

0

Y

0

X

Y

Z

Z

0

0.000

Easson

Summary of Contents for ES-3

Page 1: ...Always Committed to Quality Technology Innovation Easson Technologies Co Ltd Easson ES 3 DRO Counter Operation Manual...

Page 2: ......

Page 3: ...on Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Easson Basic Function REF datum memory Func...

Page 4: ......

Page 5: ...Easson ES 3 CE ent 1 2 3 4 5 6 7 8 9 _ 0 ref 1 2 abs inc in mm X0 Y0 X Y Z Z0 987 035 852 765 987 035 Basic Functions 1 Easson Easson...

Page 6: ......

Page 7: ...rsion 3 Set the current position for that axis to zero Purpose To set the current position to X Axis zero Example Example 2 Currently in display to switch to display metric inch Example 1 Currently in...

Page 8: ...xample Set the current position for that axis to an entered Dimension Purpose Example 1 Currently in display resolution to switch to display resolution 0 005mm 0 01mm X Easson ES 3 CE ent 1 2 3 4 5 6...

Page 9: ...e datum work piece zero position is still retained in ABS coordinate by the ES 3 Operator can then toggle between ABS absolute and INC incremental coordinates without losing the work piece datum work...

Page 10: ...Step 3 To set the X Axis zero point at the centre of the work piece Example Then half the display coordinate using centre find function as per follows Step 1 Locate the edge finder at one end of the...

Page 11: ...ref datum memory 7 Easson Easson...

Page 12: ......

Page 13: ...case of the power failure or the ES 2 being switched off we can recover the work piece datum zero position by presetting the display zero position as the stored distance from the point ref ref ref ref...

Page 14: ...ction whenever he switches on the ES 3 ABS ES 3 FIND REF ES 3 ref ref step 3 move the machine reader head across the length of the transducer until digits display in ES 3 start to count move the machi...

Page 15: ...its display start run ES 3 RECALL 0 recall work zero FIND REF find mark ref step 1 enter into the function select the recall work piece zero ref RECALL 0 step 2 select the axis of which work datum zer...

Page 16: ......

Page 17: ...ES 3 Easson ES 3 CE ent 1 2 3 4 5 6 7 8 9 _ 0 ref 1 2 abs inc in mm X0 Y0 X Y Z Z0 987 035 852 765 987 035 Digital Readout Setup Function Easson TW Always Committed to Quality Technology Innovation 13...

Page 18: ......

Page 19: ...operations cause the chaos of parameter then you need to initialize the parameter to reset the system Operational procedure Turn off the ES 3 Power on ES 3 once again when ES 3 moving in display windo...

Page 20: ......

Page 21: ...SSAGE WINDOW please key immediately then the DRO ES 3 starts entering into the SETUP function ent ent Easson ES 3 CE ent 1 2 3 4 5 6 7 8 9 _ 0 ref 1 2 abs inc in mm X0 Y0 X Y Z Z0 ES 3 ES 3 ES 3 Easso...

Page 22: ...3 ES 3 CE ent 1 2 3 4 5 6 7 8 9 _ 0 ref 1 2 abs inc in mm X0 Y0 X Y Z Z0 0 0 0 Easson ES 3 CE ent 1 2 3 4 5 6 7 8 9 _ 0 ref 1 2 abs inc in mm X0 Y0 X Y Z Z0 0 50 0 or The formula of linear error comp...

Reviews: