Page 3
Door Closer – Model DCS2024/25 Rev.1
Copyright © 2008 Eurospec
Failure to install this product as per these instructions &
dimensions shown on template will negate guarantee
Installation – Fig 61 Application – Angle of opening 180
°
Fig 61 – Transom Mounting Application (Door closer fitted on frame on push side of door)
Fig. 4
Fig. 6
Fig. 5
Fig. 1
Fig. 2
Fig. 3
Transom
Mountin
g Applic
ation
Adjust power strength of door closer here
SIZES 3, 4 & 5
SIZE 2
Adjust if
required
90
No.2
No.1
FAST SLOW
No.1 Closing Speed
No.2 Latching Speed
_
+
backcheck
Delayed Action
Illustrations show clockwise closing door
1. Ensure that the door & surrounding frame are in good
condition & the door closes freely.
2. Use Fig. 1 easi-fit template and select correct hand of door,
stick template to top corner of door and frame, ensuring
closer is mounted on frame and shoe is mounted on door.
(
See Figs. 1 & 2
)
3. Determine the power size required and using the supplied
allen key, adjust door closer strength as per chart on
template. Drill pilot holes in door and frame according to
template. Remove slide plate and fix door closer body with
screws supplied, ensuring power adjusting valve faces away
from hinge side of door. (
See Figs. 2 & 3
)
4. Carefully detach link arm from adjuster arm & securely fix
adjuster arm shoe to door ensuring the shoe is rotated
in the correct position as shown on the template. (
See Fig. 4)
Note:
Rotate shoe 180
°
for power size 2
5. Place link arm onto closer spindle at right angles
to door, fit securing screw, move link arm and re-
connect to adjuster arm. (
See Figs. 4 & 5
)
Note:
To adjust arm to suit depth of frame, loosen
nut, adjust arm & re-tighten nut.
6. Fit spindle cover cap to upperside of closer. (
See Fig. 5
)
7. Check for correct closing & latching speeds and adjust if
necessary. Adjust backcheck as required. (
See Fig.6
)
8. Stick easi-exit logo onto indent of slide plate and refit to
door closer. (
See Fig. 6
)
Note:
For delayed action model DCS2025BCDA, adjust valve as required.