Page 2
Door Closer – Model DCS2024/25 Rev.1
Copyright © 2008 Eurospec
Failure to install this product as per these instructions &
dimensions shown on template will negate guarantee
Installation – Fig 1 Application – Angle of opening 180
°
Illustrations show anti-clockwise closing door
1. Ensure that the door & surrounding frame are in good
condition & the door closes freely.
2. Select the correct hand of Fig. 1 easi-fit template
and with the door in the closed position, stick template to
top corner of door and frame. (
See Figs. 1 & 2
)
3. Determine the power size required and using the supplied
allen key, adjust door closer strength as per chart on
template. Drill pilot holes in door and frame according to
template. Remove slide plate and fix door closer body with
screws supplied ensuring power adjusting valve faces away
from hinge side of door. (
See Figs. 2 & 3
)
4. Carefully detach link arm from adjuster arm & securely fix
adjuster arm shoe to frame ensuring the shoe is rotated
in the correct position as shown on the template. (
See Fig. 4)
Note:
Rotate shoe 180
°
for power size 2
5. Place link arm onto closer spindle at right angles
to door, fit securing screw, move link arm and re-
connect to adjuster arm. (
See Figs. 4 & 5
)
Note:
To adjust arm to suit depth of frame, loosen
nut, adjust arm & re-tighten nut.
6. Fit spindle cover cap to underside of closer. (
See Fig. 5
)
7. Check for correct closing & latching speeds and
adjust if necessary. Adjust backcheck as required. (
See
Fig.6
)
8. Stick easi-exit logo onto indent of slide plate and refit to
door closer. (
See Fig. 6
)
Fig 1 – Standard Application (Door closer fitted on pull face of door)
Fig. 2
Fig. 3
Fig. 4
Fig. 6
Fig. 5
Adjust power strength of door closer here
Fig. 1
Stand
ard A
pplica
tion
Adjust if
required
FAST SLOW
No.1 Closing Speed
No.2 Latching Speed
No.2
No.1
_
+
backcheck
Delayed Action
SIZES 3, 4 & 5
SIZE 2
Note:
For delayed action model DCS2025BCDA, adjust valve as required