![EASEPAL EC-366 Maintenance Service Manual Download Page 4](http://html1.mh-extra.com/html/easepal/ec-366/ec-366_maintenance-service-manual_3404114004.webp)
中国·厦门蒙发利科技集团有限公司
Xiamen Comfort Science &Technology GROUP Co., Ltd
③
Replace main PCB.
08
No response
when pressing
the keys on
the remote
controller.
①
The terminals and wires are
poorly connected.
②
The PCB in the remote
controller fails.
①
Plug the terminal securely
or replace the wires.
②
Replace the remote
controller.
09
Back rest
cannot be
reclined or
raised
①
The terminals of reclining
actuator and wires are poorly
connected.
②
The reclining actuator fails.
③
Main PCB fails.
①
Plug the terminal
securely.
②
Replace reclining
actuator.
③
Replace main PCB.
10
Foot rest
cannot be
raised or
lowered.
①
The terminals of foot rest
actuator and wires are poorly
connected.
②
The foot rest actuator fails.
③
Main PCB fails.
①
Plug the terminal
securely.
②
Replace foot rest actuator.
③
Replace main PCB.
11
No vibration
by the motors
in the
seat-pad.
①
Print motors fail.
②
The terminals and wires are
poorly connected or the wires
fail.
③
Main PCB fails.
①
Replace the print motor.
②
Plug the terminal securely
or replace the wires.
③
Replace main PCB.
12
No gas
charging in
the seat-pad.
①
The terminal of the snuffle
valves and wires are poorly
connected.
②
The snuffle valves fail.
③
The inflator pump fails.
④
Main PCB fails.
①
Plug the terminal
securely.
②
Replace the snuffle
valves.
③
Replace the inflator
pump.
④
Replace main PCB.