Check valve Installation
Hold on the check valve with
your hands, align the box gap,
put in the check valve, and
then spin to a certain angle
until three angles of the valve
are stuck.
Installation is complete.
Carbon Filter
Activated carbon filter can be
used to trap odors. Normally
the activated carbon filter
should be changed at three
or six months according to
your cooking habit. The
installation procedure of acti-
vated carbon filter is as below.
Slide the drawer assembly of
cooker hood.
In order to install the activated
carbon filter, the metallic anti-
grease filter should be de-
tached first. Press the lock and
pull it downward.
Put the activated carbon filter
into the unit rotating it in anti-
clockwise direction. Repeat
the same on the other side.
Put back the grease filter in
position.
When activated carbon filter
attached,
the suction power will
be lowered.
Venting knob position
Extraction-air mode: Turn
the venting knob here
means venting outside
Circulating-air mode:
Turn the venting knob
here means recirculation
Information
8
V.5