30
E5/
E6
Bad induction hob
heat radiation
Please restart after the
induction hob cools down.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and
damages to the induction hob.
9. Installation
9.1 Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select
heat-resistant and insulated work surface material (Wood and similar fibrous or
hygroscopic material shall not be used as work surface material unless
impregnated) to avoid the electrical shock and larger deformation caused by the
heat radiation from the hotplate. As shown below:
Note: The safety distance between the sides of the hob and the
inner surfaces of the worktop should be at least 3mm.
V.2