background image

4

2.2 Brief introduction of product structure

2.3 Internal Wire Diagram

(Note:All dimensions are in mm)

A
B
C
D

450
200

340
200

WIRING DIAGRAM

Thermometer

Hot water 

outlet

Cold water inlet

Inner tank
Thermal 

insulation

Heating 

element

Anode

Shell

Power 

cord

Heating indicator light

600
450

450
200

805
450

450
200

970
450

603

EME50L

EME80L

EME100L

EME30L

340

Thermal 

Cut Out

Thermostat

Heating Indicator light

Heating Element

Brown

Blue

Yellow/Green

E

N

L

A

B

C

D

V.1

Summary of Contents for EME30L

Page 1: ...Manual de Instrucciones Para modelos EME30L EME50L EME80L EME100L www easelectric es V 1...

Page 2: ...e do este manual Para m s detalles sobre la instalaci n y mantenimiento por favor lea los capitulos espec ficos de este manual INDICE TITULO PAG 1 Precauciones 2 2 Presentaci n del producto 3 3 Ubicac...

Page 3: ...or debe ser instalado con tuber a de entrada del agua fr a del calentador y asegurar que no est expuesto al fuego El agua puede derramarse desde la v lvula de alivio de presi n por lo que la tuber a d...

Page 4: ...E30L EME50L Potencia Nominal W Volumen L Presi n Nominal MPa Temperatura m xima de agua C Clase de protecci n Grado de aislamiento a la humedad I I IPX4 75 0 75 220 240 1500 80 EME80L I IPX4 75 0 75 2...

Page 5: ...m metro Salida de agua caliente Tuber a de agua fr a Tanque interno Aislamiento t rmico Elemento de calefacci n nodo Capa exterior Cable de alimentaci n Luz indicadora de calor 600 450 450 200 805 450...

Page 6: ...ima del calentador La altura del z calo al suelo no ser inferior a 1 8 m ver figura 3 Si hay fallo en el cable de alimentaci n debe ser sustituido por los fabricantes organismos o persona cualificada...

Page 7: ...del aparato en caso de ser necesario Si los usuarios desean realizar un sistema de suministro de m ltiples v as consulte el m todo mostrado en la figura 5 para la conexi n de las tuber as 6 Fig 4 Ent...

Page 8: ...e agua debido a la congelaci n del agua en el tanque interno Consulte el apartado de precauciones en este manual para drenar el agua Para asegurar el funcionamiento prolongado del calentador de agua s...

Page 9: ...2 La presi n hidr ulica es demasiado baja 3 La v lvula de entrada del agua corriente est cerrada 1 Espere a que se restaure el suministro de agua corriente 2 Utilice el termo cuando la presi n del ag...

Page 10: ...reguladora No 814 2013 para calentador el ctrico de agua con dep sito y logr una eficiencia energ tica de calentamiento de agua de wh 32 que corresponde a la clase de eficiencia de calentamiento de a...

Page 11: ...ntador el ctrico de agua con dep sito y logr una eficiencia energ tica de calentamiento de agua de wh 37 que corresponde a la clase de eficiencia de calentamiento de agua C De acuerdo con el Anexo II...

Page 12: ...para calentador el ctrico de agua con dep sito y logr una eficiencia energ tica de calentamiento de agua de wh 38 que corresponde a la clase de eficiencia de calentamiento de agua C De acuerdo con el...

Page 13: ...calentador el ctrico de agua con dep sito y logr una eficiencia energ tica de calentamiento de agua de wh 37 que corresponde a la clase de eficiencia de calentamiento de agua C De acuerdo con el Anex...

Page 14: ...presente una reducci n de tama o superior a 2 3 del tama o original o este cubierto de cal en su totalidad Los materiales rotos o deteriorados por desgaste o uso normal del aparato Las operaciones de...

Page 15: ...tallation or failing to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to below chapters TABLE OF CONTENTS TITLE PA...

Page 16: ...r inlet of this heater and make sure it is not exposed in the foggy The water may be outflowed from pressure relief valve so the outflow pipe must open wide in the air In order to drain away the water...

Page 17: ...0 240 1500 1500 30 50 EME30L EME50L Rated Power W Volume L Rated Pressure MPa Max Of Water Temperature C Protection Class Waterproof Grade I I IPX4 75 0 75 220 240 1500 80 EME80L I IPX4 75 0 75 220 24...

Page 18: ...DIAGRAM Thermometer Hot water outlet Cold water inlet Inner tank Thermal insulation Heating element Anode Shell Power cord Heating indicator light 600 450 450 200 805 450 450 200 970 450 603 EME50L EM...

Page 19: ...ght above the heater The height of the socket to the ground shall not be less than 1 8m see Fig 3 If there is fault on power cable it should be replaced by the manufacturers agencies or qualified pers...

Page 20: ...n the right side of the electric heater to convenient the maintenance of the heater if necessary If the users want to realize a multi way supply system refer to the method shown in fig 5 for connectio...

Page 21: ...of the water heater due to water freezing in the internal tank Refer Cautions in this manual for the method to drain away the water from the inner container To ensure long reliable water heater operat...

Page 22: ...pressure is too low 3 The inlet valve of running water is not open 1 Wait for restoration of running water supply 2 Use the heater again when the hydraulic pressure is increased 3 Open the inlet valv...

Page 23: ...ls and corresponds to the requirements of the commission regulation standards No 814 2013 for electrical storage water heater and achieved a water heating energy efficiency of wh 32 In accordance with...

Page 24: ...e requirements of the commission regulation standards No 814 2013 for electrical storage water heater and achieved a water heating energy efficiency of wh 37 In accordance with Annex Enercy Efficiency...

Page 25: ...s to the requirements of the commission regulation standards No 814 2013 for electrical storage water heater and achieved a water heating energy efficiency of wh 38 In accordance with Annex Enercy Eff...

Page 26: ...o the requirements of the commission regulation standards No 814 2013 for electrical storage water heater and achieved a water heating energy efficiency of wh 37 In accordance with Annex Enercy Effici...

Page 27: ...ch the anode has a size reduction greater than 2 3 of the original size or is covered with lime in its entirety Materials broken or damaged due to wear or normal use of the appliance The operations of...