DO-160 Environmental Qualification Form
The following table is the DO-160 testing Environmental Qualification form.
Nomenclature: Rechargeable Lithium Battery System
Model: ETX680-24-TSO
TSO Number:
Manufacturer’s Specification: N/A
Manufacturer: EarthX
Address: 955 Merchant Ct, Windsor, CO 80550
Revision & Change Number of DO-160: G, Dec8, 2010
Date Tested: Oct 30, 2020
Conditions
Section
Description of Tests Conducted
Temperature and Altitude
Low Temperature
High Temperature
Ground Survival
Loss of Cooling
Altitude
Decompression
Overpressure
4.0
4.5.2
4.5.4
4.5.1&4.5.3
-
4.6.1
4.6.2
4.6.3
Equipment tested to Categories:
B4, -30
°
C
B3
B3
Equipment Category X, no auxiliary cooling
Equipment tested to Cat. B3
Equipment tested to Cat. A3, 50,000ft
Equipment tested to Cat. A3, -15,000ft
Temperature Variation
5
Equipment tested to Categories B
Humidity
6
Equipment tested to Categories A
Operational Shock and Crash Safety
7
Equipment tested to Categories B
Vibration
8
Equipment tested to Category R, S, and U
aircraft zone 1 and 2 for fixed wing turbojet
engine aircraft, fixed wing unducted turbofan
engine aircraft, helicopters, and fixed wing
reciprocating/turbojet engine aircraft (multi or
single engine) less than 5,700kg using vibration
test curves B, B1, C, C1, G, G1, L, M, R and F
Explosive Atmosphere
9
Equipment identified as Category X, no test
performed
Waterproofness
10
Equipment tested to Categories R
Fluid Susceptibility
11
Equipment tested to Categories F
Equipment spray tested
Sand and Dust
12
Equipment identified as Category X, no test
performed
Fungus
13
Equipment identified as Category X, no test
performed
Salt Fog
14
Equipment tested to Categories S
Magnetic Effect
15
Equipment tested to Categories X, no test
performed
Power Input
16
Equipment tested to Categories B(RX), loss of
power or low voltage tests not applicable for
the equipment is a power source
Voltage Spike
17
Equipment tested to Categories A
Audio Frequency Conducted
Susceptibility
18
Equipment tested to Categories B