Assembly and Operation Instructions
2170_M52164_RevJune2021
PAGE 7
CALIBRATION
Step 15:
Pull lever back to setting “30” as
shown. Next push pivot & bracket forward so
that the shut off plate in the hopper is in the full
open position.
REMEMBER SETTING “30” ON
THE FLOW CONTROL LEVER MUST PLACE THE
SHUT-OFF PLATE IN THE FULL OPEN POSITION
TO BE PROPERLY CALIBRATED
. Now tighten the
nuts against the PIVOT BRACKET to prevent
change in calibration.
NOTE
: Tension on the flow control lever may
be adjusted by tightening or loosening the
tension nut as shown.
Step 16:
Insert agitator to pinion shaft on
inside of hopper.
Note
: the position of flat side of the agitator.
This pin should be installed as shown.