EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS
17
GAS PRESSURE
Please follow the gas requirements listed below:
Inlet Gas Pressure 7” W.C. for Natural Gas - 10”W.C. for LP gas
Manifold Pressure: The amounts listed below are set at the factory.
Natural Gas Manifold pressure
90-PAGW
4” W.C.
110-PAGW
4” W.C.
130-PAGW
4.5” W.C.
160-PAGW
4.5” W.C.
LP Gas Manifold pressure
90-PAGW
7” W.C.
110-PAGW
7” W.C.
130-PAGW
7” W.C.
160-PAGW
7” W.C.
The inlet and manifold (outlet) pressure taps are located at the Gas Control Valve. This
part is in the burner controls box and attached to the oven support stand.