background image

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 

 

      

       6 

 

should be retained in the closed container until all cinders have thoroughly cooled. After ashes have been removed 
mop down hearth with clean damp cloths. 

 
3. 

Store wood in a cool, dry place well away from any source of flame or heat.  If stored outside, keep the fuel covered 
to protect from rain or snow.  If stored inside, fuel should be kept in a covered metal container at least 6 inches  

 
 
 

above  the  floor.    Keep  paper,  rags  and  other easily ignited materials away from wood fuel. Refer to NFPA 96 for 
wood storage procedures. 

 
 
4. 

At least at the end of each shift the area around the unit must be thoroughly cleaned of all wood, wood shavings, 
embers,  ashes  and  other  refuse.    All  mats  (if  present,  mats  must  be  non-combustible)  must  be  picked  up  and 
carefully  swept  along  with  the  floor  during  this  clean  up.    After  clean  up  around  the  unit,  brooms  should  be 
thoroughly wet down to extinguish hot coals, then stored well away from combustible materials. 

 
5. 

Creosote - Formation and need for removal 

 

WHEN  WOOD  IS  BURNED  SLOWLY,  IT  PRODUCES  TAR  AND  OTHER  ORGANIC  VAPORS,  WHICH 
COMBINE  WITH  EXPELLED  MOISTURE  TO  FORM  CREOSOTE.    THE  CREOSOTE  VAPORS  CONDENSE  IN 
THE RELATIVELY COOL OVEN FLUE AND EXHAUST HOOD OF DUCT, PARTICULARLY A SLOW  

 

burning  fire.    As  a  result,  creosote  residue  accumulates  on  the  flue  lining  and  exhaust  hood.    When  ignited,  this 
creosote makes an extremely hot fire. 
 
The oven flue, exhaust duct and power ventilator should be inspected at least twice monthly during normal use to 
determine if creosote buildup has occurred.  If creosote and/or grease has accumulated, it should be removed to 
reduce the risk of fire.  Experienced chimney and duct servicing personnel who are qualified in the removal of both 
creosote and grease from flues and ducts should be contracted to do the inspection and cleaning. The inspection 
and  cleaning  schedule  must  be  adjusted  as  needed  to  prevent  the  buildup  of  creosote  and/or  grease.  More 
frequent inspections and cleanings are indicated   when  excessive  buildup  occurs  between  regular  inspections.  
The rate of accumulation can increase whenever 1) there is a change in the use of the oven 2) when the type or 
moisture content of the   firewood changes 3) when other variables change. 
 
The oven, exhaust hood and grease filters should be cleaned on a daily basis. The Grease filters can be removed 
and cleaned in a dishwasher or sink.  Refer to the NFPA 96 requirements and the Exhaust Hood or Grease Duct 
manufacturer's instructions for inspection, maintenance and cleaning of the venting system. 

 

DO NOT CLEAN UNIT, HOOD OR VENT WHILE HOT OR WHILE OVEN IS BEING FIRED. 

 

6. 

The entire unit and vent system should be inspected frequently for proper fit, operation and soundness of   parts.  
If any malfunctioning parts, leakage, deterioration, or other problems are noted, contact your dealer to inspect and 
repair the unit, or qualified ventilation repair service to inspect and repair the vent   system.  DO NOT OPERATE 
THE UNIT IF INSTALLED OR FUNCTIONING IMPROPERLY. 

 
7. 

All maintenance must be performed by qualified personnel. 

 
8. 

Refer to NFPA 96 for procedures for inspection, cleaning and maintenance for solid fuel cooking. 

 
9. 

SERVICE OF OVEN TEMP. MONITORING EQUIPMENT 

 

A) 

Replace with Temp. gauge rated 6-14 VDC, Temp. range -580F to 9320F.  (AJ Antunes – TTC) 

 

B) 

Replace AC adapter with U.L. listed plug-in class 2 transformer rated input 120 VAC, 60 HZ,  

 

   

9 Watts, output 12 VDC, 200 Ma. 

 

C) 

Replace Thermocouple with a metal sheathed Type-"K" thermocouple, Min. 6 ft.

 

 
10.  Save these instructions for future reference. 

 
 

Summary of Contents for GAS FIRED OVEN

Page 1: ...ROMINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WAR I G IMPROPER INSTALLATION ADJUSTMENT ALTERATION S...

Page 2: ...GRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION CODE CAN CGA B14...

Page 3: ...STRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNEL WATC...

Page 4: ...TE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLOSE TO T...

Page 5: ...d container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper or ot...

Page 6: ...ced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection and cle...

Page 7: ...URNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER ASSEM...

Page 8: ...OR COUNTER CLOCKWISE 5 RED BUTTO USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPERATURE SEE PAGE LABELED SWITCH DIAGRAM LAYOUT OPERATION FIRI G OVE OTE DO OT CLOSE DOOR WHILE OVE IS BEI G FIRED...

Page 9: ...USE ANY CLEANING AGENTS IN THE OVEN SHUTTI G DOW OVE TURN MAIN POWER SWITCH TO OFF POSITION IF OVEN IS BEING SHUT DOWN FOR THE NIGHT GAS CONTROL VALVE SHOULD BE TURNED TO OFF POSITION SAVE THESE I STR...

Page 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 10 GAS BURNER CONTROLS E S ARTH TONE LOS ANGELES OFF ON HI LO HI OFF 000 1 2 3 4 5...

Page 11: ...en may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended to at...

Page 12: ...STALLATION INSTRUCTIONS 12 GAS BURNER WOOD All wood fired in a gas wood combination o ven should be located on the opposite side of the gas bu rner Take caution to avoid ashes from entering the gas bu...

Page 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG...

Page 14: ...opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed for co...

Page 15: ...sure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable lid m...

Page 16: ...ER CLOCKWISE TO DECREASE AND CLOCKWISE TO INCREASE REMOVE OVE DOOR THE DOOR SHOULD OT BE CLOSED WHE OVE IS FIRED WITH A 2 SIDED OVE YOU CA HAVE O E DOOR CLOSED MOVE HI LO HI OFF SWITCH TO HI LO UPWARD...

Page 17: ...d Pressure The amounts listed below are set at the factory Natural Gas Manifold pressure 90 PAGW 4 W C 110 PAGW 4 W C 130 PAGW 4 5 W C 160 PAGW 4 5 W C LP Gas Manifold pressure 90 PAGW 7 W C 110 PAGW...

Reviews: